Rapid and ultra-sensitive lateral flow assay for pathogens based on multivalent aptamer and magnetic nanozyme

Xiuping Li, Guowen Li, Qiuli Pan, Feng Xue, Zhouping Wang, Chifang Peng

Biosensors and Bioelectronics · 2024-04 · 250 · 116044

DOI: 10.1016/j.bios.2024.116044 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-04. Verfasst von Xiuping Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Food Science and Resources, Jiangnan University, Lihu Road 1800, Wuxi 214122, PR China; School of Food Science and Technology…. Hauptthemen laut MEDLINE: Biosensing Techniques, Aptamers, Nucleotide. Die Arbeit wurde bisher 71-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultra-sensitive LFA methods for pathogen detection commonly depended on tedious and time-consuming nucleic acid amplification. Here, a high affinity multivalent aptamer (multi-Apt) for S. aureus was obtained through exquisite engineering design. The scaffold and conformation of the multi-Apt were found to be key factors in the detection signal of aptsensors. After optimization, the binding affinity of the multi-Apt to S. aureus was improved by more than 8-fold from 135.9 nM to 16.77 nM. By the joint use of the multi-Apt and a multifunctional nanozyme Fe3O4@MOF@PtPd, a fast and ultra-sensitive LFA for S. aureus was developed (termed MA-MN LFA). In this method, a Fe3O4@MOF@PtPd nanozyme was modified with vancomycin and could efficiently capture and separate S. aureus. Moreover, the multi-Apt worked together with the nanozyme to bind with S. aureus to form a ternary complex at the same time, which simply the fabrication of LFA strip. The developed MA-MN LFA could detect S. aureus as low as 2 CFU/mL within 30 min and a wide linear range of 10-1 × 108 CFU/mL was obtained. The detection is easily operated, fast (can be completed within 30 min) and versatile for Gram-positive pathogens, thus has great potential as a powerful tool in pathogen detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesAptamers, NucleotideStaphylococcus aureusVancomycinOligonucleotidesMagnetic Phenomena

Stichwörter der Autor:innen

Lateral flow assayMultifunctional nanozymeMultivalent aptamerS. aureus

Substanzen

VancomycinOligonucleotidesAptamers, Nucleotide

Autor:innen und Institutionen

  • State Key Laboratory of Food Science and Resources, Jiangnan University, Lihu Road 1800, Wuxi 214122, PR China; School of Food Science and Technology, Jiangnan University, Lihu Road 1800, Wuxi 214122, PR China.
  • Shandong Institute for Food and Drug Control, Jinan 250101, PR China.
  • College of Veterinary Medicine, Nanjing Agricultural University, Nanjing 210095, PR China.
  • State Key Laboratory of Food Science and Resources, Jiangnan University, Lihu Road 1800, Wuxi 214122, PR China; School of Food Science and Technology, Jiangnan University, Lihu Road 1800, Wuxi 214122, PR China; Internat…

Förderung

  • National Natural Science Foundation of China
  • National Key Research and Development Program of China

Zitieren

APA

Li, X., Li, G., Pan, Q., Xue, F., Wang, Z., & Peng, C. (2024). Rapid and ultra-sensitive lateral flow assay for pathogens based on multivalent aptamer and magnetic nanozyme. Biosensors and Bioelectronics, 250, 116044. https://doi.org/10.1016/j.bios.2024.116044

Vancouver

Li X, Li G, Pan Q, Xue F, Wang Z, Peng C. Rapid and ultra-sensitive lateral flow assay for pathogens based on multivalent aptamer and magnetic nanozyme. Biosensors and Bioelectronics. 2024;250:116044. doi:10.1016/j.bios.2024.116044

BibTeX
@article{Li2024,
  author = {Li, Xiuping and Li, Guowen and Pan, Qiuli and Xue, Feng and Wang, Zhouping and Peng, Chifang},
  title = {Rapid and ultra-sensitive lateral flow assay for pathogens based on multivalent aptamer and magnetic nanozyme},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {250},
  pages = {116044},
  doi = {10.1016/j.bios.2024.116044}
}
Kostenlos starten →