Fluorescent aptasensor based on magnetic bead–assisted displacement reaction for monitoring vancomycin in plasma
Analytica Chimica Acta · 2026
DOI: 10.1016/j.aca.2025.344895 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Cheng-Shiuan Hsieh und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, National Chung Cheng University, Chia- Yi, 621301, Taiwan. Hauptthemen laut MEDLINE: Vancomycin, Aptamers, Nucleotide, Biosensing Techniques, Anti-Bacterial Agents. Die Arbeit nennt 35 Literaturangaben. Gefördert von: National Science and Technology Council, Ditmanson Medical Foundation Chia-Yi Christian Hospital.
Abstract (Originalsprache)
BACKGROUND: Vancomycin is a glycopeptide antibiotic commonly prescribed for infection by methicillin-resistant Staphylococcus aureus. Due to its narrow therapeutic window and time-dependent bactericidal activity, therapeutic drug monitoring is essential to optimize dosing and minimize toxicity. Immunoassay-based approaches have traditionally been widely used; however, they often require long assay times and are susceptible to matrix interferences, which limit their applicability for rapid clinical use. To enhance the development of point-of-care testing for therapeutic drug monitoring, we developed a fluorescent aptasensor based on a magnetic bead-assisted displacement reaction for the quantification of vancomycin in human plasma. RESULTS: The sensing mechanism is based on the competition between vancomycin and a complementary single-stranded DNA (cDNA) for binding to a fluorescent aptamer. The cDNA-aptamer complex was immobilized on magnetic beads, and upon addition of vancomycin, the stronger binding affinity between vancomycin and the aptamer displaced the cDNA, releasing the aptamer-vancomycin complex into the supernatant. After magnetic separation, the fluorescence intensity of the supernatant was measured to quantify vancomycin concentration. The optimized experimental conditions were using a 16-mer cDNA and 1 × PBS buffer containing 10 mM MgCl2 at pH 7.0, with a total reaction time of only 15 min. The aptasensor exhibited a linear response for vancomycin in plasma over the range of 1-25 μM, with a low detection limit of 0.5 μM. SIGNIFICANCE: The developed assay was successfully applied to clinical plasma samples, and the results showed good agreement with those obtained by enzyme-linked immunosorbent assay, confirming the accuracy and potential of this aptasensor for clinical application. This aptasensor provides a simple, rapid, and cost-effective strategy for therapeutic drug monitoring of vancomycin in clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry and Biochemistry, National Chung Cheng University, Chia- Yi, 621301, Taiwan.
- Department of Plastic Surgery, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, 60002, Taiwan.
- Department of Orthopaedics, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, 60002, Taiwan.
- Department of Pharmacy, Kaohsiung Medical University Hospital, Kaohsiung, 807378, Taiwan.
- Department of Chemistry and Biochemistry, National Chung Cheng University, Chia- Yi, 621301, Taiwan; Center for Nano Bio-Detection, National Chung Cheng University, Chia-Yi, 621301, Taiwan; School of Pharmacy, College o…
- Department of Pathology, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, 60002, Taiwan; Department of Cosmetic Science, Chia Nan University of Pharmacy and Science, Tainan, 71710, Taiwan; Ph.D. Program…
Förderung
- National Science and Technology Council
- Ditmanson Medical Foundation Chia-Yi Christian Hospital
Zitieren
APA
Hsieh, C. S., Tsai, H. Y., Tsai, T. C., Wang, Y. C., Cheng, Y. T., Liou, J. R., Liu, M. Y., Chen, Y. L., & Chen, C. C. (2026). Fluorescent aptasensor based on magnetic bead–assisted displacement reaction for monitoring vancomycin in plasma. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.344895
Vancouver
Hsieh CS, Tsai HY, Tsai TC, Wang YC, Cheng YT, Liou JR, et al. Fluorescent aptasensor based on magnetic bead–assisted displacement reaction for monitoring vancomycin in plasma. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2025.344895
BibTeX
@article{Hsieh2026,
author = {Hsieh, Cheng-Shiuan and Tsai, Hsu-Yun and Tsai, Ting-Chien and Wang, Yang-Chun and Cheng, Yi-Tung and Liou, Jing-Ru and Liu, Meng-Yu and Chen, Yen-Ling and Chen, Chien-Chin},
title = {Fluorescent aptasensor based on magnetic bead–assisted displacement reaction for monitoring vancomycin in plasma},
journal = {Analytica Chimica Acta},
year = {2026},
doi = {10.1016/j.aca.2025.344895}
}
EUVIMED