Point-of-care diagnosis of pre-eclampsia based on microfiber Bragg grating biosensor

Shifang Cao, Ruiping Chen, Qiaochu Yang, Xin He, Francesco Chiavaioli, Yang Ran, Bai-Ou Guan

Biosensors and Bioelectronics · 2024-04 · 249 · 116014

DOI: 10.1016/j.bios.2024.116014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-04. Verfasst von Shifang Cao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Laboratory Center, The First Clinical Medical College, Jinan University, Guangzhou, 510630, China; Guangdong Provincial Key Laboratory of Op…. Hauptthemen laut MEDLINE: Pre-Eclampsia, Biosensing Techniques. Die Arbeit wurde bisher 45-mal zitiert (Crossref) und nennt 55 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pre-eclampsia is a serious multi-organ complication that severely threatens the safety of pregnant women and infants. To accurate and timely diagnose pre-eclampsia, point-of-care (POC) biosensing of the specific biomarkers is urgently required. However, one of the key biomarkers of pre-eclampsia, placental growth factor (PlGF), has a reduced level of expression in patients, which challenges the quantification capability and Limit-of-detection (LOD) of biosensors. Herein, we reported a microfiber Bragg grating biosensor for the quantification of PlGF in clinical serum samples. The Bragg grating was inscribed in a unilateral tapered fiber to generate the segmented Fabry-Perot spectrum for improving the capability of detection. Furthermore, a temperature-calibrated Bragg grating was added to enable dual parametric detection of PlGF and temperature simultaneously for removing the crosstalk. Finally, the biosensor was envisaged to be perfectly compatible with microfluidic chips, and thus dramatically reducing the sample consumption to as small as 10 μL. The proposed biosensor can respond to PlGF with concentrations ranging from 5 to 120 pg mL-1, attaining a LOD of 5 pg mL-1 of clinical relevance. More importantly, the biosensor achieved micro volume detection of clinical serum samples from patients, and the ROC curve with an AUC of 0.977 confirmed the viability of the device. Our study paves the way to a new idea for cost-effective and high-precision screening of patients with pre-eclampsia, and hence envisages a promising prospect for point-of-care (POC) diagnosis of patients with pre-eclampsia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pre-EclampsiaBiosensing TechniquesPregnancyFemaleHumansPlacenta Growth FactorPoint-of-Care SystemsBiomarkers

Stichwörter der Autor:innen

BiosensorBragg gratingOptical microfibersPlacental growth factorPoint-of-care diagnosisPre-eclampsia

Substanzen

Placenta Growth FactorBiomarkers

Autor:innen und Institutionen

  • Clinical Laboratory Center, The First Clinical Medical College, Jinan University, Guangzhou, 510630, China; Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Institute of Photonics Technol…
  • Department of Obstetrics and Gynecology, The First Clinical Medical College, Jinan University, Guangzhou, 510630, China. Electronic address: 609833909@qq.com.
  • Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Institute of Photonics Technology, Jinan University, Guangzhou, 510632, China.
  • Clinical Laboratory Center, The First Clinical Medical College, Jinan University, Guangzhou, 510630, China. Electronic address: 396663955@qq.com.
  • National Research Council of Italy (CNR), Institute of Applied Physics "Nello Carrara", Sesto Fiorentino, 50019, Italy.
  • Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Institute of Photonics Technology, Jinan University, Guangzhou, 510632, China. Electronic address: tranyang@jnu.edu.cn.

Zitieren

APA

Cao, S., Chen, R., Yang, Q., He, X., Chiavaioli, F., Ran, Y., & Guan, B. O. (2024). Point-of-care diagnosis of pre-eclampsia based on microfiber Bragg grating biosensor. Biosensors and Bioelectronics, 249, 116014. https://doi.org/10.1016/j.bios.2024.116014

Vancouver

Cao S, Chen R, Yang Q, He X, Chiavaioli F, Ran Y, et al. Point-of-care diagnosis of pre-eclampsia based on microfiber Bragg grating biosensor. Biosensors and Bioelectronics. 2024;249:116014. doi:10.1016/j.bios.2024.116014

BibTeX
@article{Cao2024,
  author = {Cao, Shifang and Chen, Ruiping and Yang, Qiaochu and He, Xin and Chiavaioli, Francesco and Ran, Yang and Guan, Bai-Ou},
  title = {Point-of-care diagnosis of pre-eclampsia based on microfiber Bragg grating biosensor},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {249},
  pages = {116014},
  doi = {10.1016/j.bios.2024.116014}
}
Kostenlos starten →