EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Bowtie Nanoantenna LSPR Biosensor for Early Prediction of Preeclampsia

Ke Yi iD, Mengyin Ao, Ting Ding, Danxi Zheng, Lin Li iD

Biosensors · 24.06.2024 · 14 (7) · 317

DOI: 10.3390/bios14070317 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 24.06.2024. Verfasst von Ke Yi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Gynecology Department of West China Second University Hospital, Sichuan University, Chengdu 610041, China. Hauptthemen laut MEDLINE: Pre-Eclampsia, Biosensing Techniques, Placenta Growth Factor. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Department of Sichuan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The concentration of the placental circulating factor in early pregnancy is often extremely low, and the traditional prediction method cannot meet the clinical demand for early detection preeclampsia in high-risk gravida. It is of prime importance to seek an ultra-sensitive early prediction method.

Methods

In this study, finite-different time-domain (FDTD) and Discrete Dipole Approximation (DDA) simulation, and electron beam lithography (EBL) methods were used to develop a bowtie nanoantenna (BNA) with the best field enhancement and maximum coupling efficiency. Bio-modification of the placental circulating factor (sFlt-1, PLGF) to the noble nanoparticles based on the amino coupling method were explored. A BNA LSPR biosensor which can specifically identify the placental circulating factor in preeclampsia was constructed.

Results

The BNA LSPR biosensor can detect serum placental circulating factors without toxic labeling. Serum sFlt-1 extinction signal (Δλmax) in the preeclampsia group was higher than that in the normal pregnancy group (14.37 ± 2.56 nm vs. 4.21 ± 1.36 nm), p = 0.008, while the serum PLGF extinction signal in the preeclampsia group was lower than that in the normal pregnancy group (5.36 ± 3.15 nm vs. 11.47 ± 4.92 nm), p = 0.013. The LSPR biosensor detection results were linearly consistent with the ELISA kit.

Conclusions

LSPR biosensor based on BNA can identify the serum placental circulating factor of preeclampsia with high sensitivity, without toxic labeling and with simple operation, and it is expected to be an early detection method for preeclampsia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pre-EclampsiaBiosensing TechniquesPlacenta Growth FactorPregnancyFemaleHumansVascular Endothelial Growth Factor Receptor-1Surface Plasmon Resonance

Stichwörter der Autor:innen

bowtie nanoantennaearly predictionlocalized surface plasmon resonancepreeclampsia

Substanzen

Placenta Growth FactorVascular Endothelial Growth Factor Receptor-1FLT1 protein, human

Autor:innen und Institutionen

  • Gynecology Department of West China Second University Hospital, Sichuan University, Chengdu 610041, China.
  • Key Laboratory of Birth Defects and Related Diseases of Women and Children, Ministry of Education, Sichuan University, Chengdu 610041, China.

ORCID-Profile: Ke Yi, Lin Li

Förderung

  • Science and Technology Department of Sichuan Province

Zitieren

APA

Yi, K., Ao, M., Ding, T., Zheng, D., & Li, L. (2024). Bowtie Nanoantenna LSPR Biosensor for Early Prediction of Preeclampsia. Biosensors, 14(7), 317. https://doi.org/10.3390/bios14070317

Vancouver

Yi K, Ao M, Ding T, Zheng D, Li L. Bowtie Nanoantenna LSPR Biosensor for Early Prediction of Preeclampsia. Biosensors. 2024;14(7):317. doi:10.3390/bios14070317

BibTeX
@article{Yi2024,
  author = {Yi, Ke and Ao, Mengyin and Ding, Ting and Zheng, Danxi and Li, Lin},
  title = {Bowtie Nanoantenna LSPR Biosensor for Early Prediction of Preeclampsia},
  journal = {Biosensors},
  year = {2024},
  volume = {14},
  number = {7},
  pages = {317},
  doi = {10.3390/bios14070317}
}
Kostenlos starten →