Bowtie Nanoantenna LSPR Biosensor for Early Prediction of Preeclampsia
Biosensors · 24.06.2024 · 14 (7) · 317
DOI: 10.3390/bios14070317 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 24.06.2024. Verfasst von Ke Yi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Gynecology Department of West China Second University Hospital, Sichuan University, Chengdu 610041, China. Hauptthemen laut MEDLINE: Pre-Eclampsia, Biosensing Techniques, Placenta Growth Factor. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Department of Sichuan Province.
Abstract (Originalsprache)
Objective
The concentration of the placental circulating factor in early pregnancy is often extremely low, and the traditional prediction method cannot meet the clinical demand for early detection preeclampsia in high-risk gravida. It is of prime importance to seek an ultra-sensitive early prediction method.
Methods
In this study, finite-different time-domain (FDTD) and Discrete Dipole Approximation (DDA) simulation, and electron beam lithography (EBL) methods were used to develop a bowtie nanoantenna (BNA) with the best field enhancement and maximum coupling efficiency. Bio-modification of the placental circulating factor (sFlt-1, PLGF) to the noble nanoparticles based on the amino coupling method were explored. A BNA LSPR biosensor which can specifically identify the placental circulating factor in preeclampsia was constructed.
Results
The BNA LSPR biosensor can detect serum placental circulating factors without toxic labeling. Serum sFlt-1 extinction signal (Δλmax) in the preeclampsia group was higher than that in the normal pregnancy group (14.37 ± 2.56 nm vs. 4.21 ± 1.36 nm), p = 0.008, while the serum PLGF extinction signal in the preeclampsia group was lower than that in the normal pregnancy group (5.36 ± 3.15 nm vs. 11.47 ± 4.92 nm), p = 0.013. The LSPR biosensor detection results were linearly consistent with the ELISA kit.
Conclusions
LSPR biosensor based on BNA can identify the serum placental circulating factor of preeclampsia with high sensitivity, without toxic labeling and with simple operation, and it is expected to be an early detection method for preeclampsia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Gynecology Department of West China Second University Hospital, Sichuan University, Chengdu 610041, China.
- Key Laboratory of Birth Defects and Related Diseases of Women and Children, Ministry of Education, Sichuan University, Chengdu 610041, China.
Förderung
- Science and Technology Department of Sichuan Province
Zitieren
APA
Yi, K., Ao, M., Ding, T., Zheng, D., & Li, L. (2024). Bowtie Nanoantenna LSPR Biosensor for Early Prediction of Preeclampsia. Biosensors, 14(7), 317. https://doi.org/10.3390/bios14070317
Vancouver
Yi K, Ao M, Ding T, Zheng D, Li L. Bowtie Nanoantenna LSPR Biosensor for Early Prediction of Preeclampsia. Biosensors. 2024;14(7):317. doi:10.3390/bios14070317