Contact lens sensor for ocular inflammation monitoring
Biosensors and Bioelectronics · 2024-04 · 249 · 116003
DOI: 10.1016/j.bios.2024.116003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-04. Verfasst von Yuqi Shi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, UK. Hauptthemen laut MEDLINE: Biosensing Techniques, Contact Lenses. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Contact lens sensors have been emerging as point-of-care devices in recent healthcare developments for ocular physiological condition monitoring and diagnosis. Fluorescence sensing technologies have been widely applied in contact lens sensors due to their accuracy, high sensitivity, and specificity. As ascorbic acid (AA) level in tears is closely related to ocular inflammation, a fluorescent contact lens sensor incorporating a BSA-Au nanocluster (NC) probe is developed for in situ tear AA detection. The NCs are firstly synthesized to obtain a fluorescent probe, which exhibits high reusability through the quench/recover (KMnO4/AA) process. The probe is then encapsulated with 15 wt% of poly(vinyl alcohol) (PVA) and 1.5 wt% of citric acid (CA) film, and implemented on a closed microfluidic contact lens sensing region. The laser-ablated microfluidic channel in contact lens sensors allows for tear fluid to flow through the sensing region, enabling an in-situ detection of AA. Meanwhile, a smartphone application accompanied by a customized 3D printed readout box is developed for image caption and algorism to quantitative analysis of AA levels. The contact lens sensor is tested within the readout box and the emission signal is collected through the smartphone camera at room temperature with an achieved LOD of 0.178 mmol L-1 (0.0-1.2 mmol L-1). The operational and storage lifetime is also evaluated to characterize the sensor properties and resulted in 20 h and 10 days, respectively. The reusable AA contact lens sensor is promising to lead to an alternative accessible diagnostic method for ocular inflammation in point-of-care settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, UK.
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, UK. Electronic address: yubing.hu@imperial.ac.uk.
- West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu, 610041, China; Jinfeng Laboratory, Chongqing, 401329, China. Electronic address: jiangnansophia@scu.edu.cn.
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, UK. Electronic address: a.yetisen@imperial.ac.uk.
Zitieren
APA
Shi, Y., Wang, L., Hu, Y., Zhang, Y., Le, W., Liu, G., Tomaschek, M., Jiang, N., & Yetisen, A. K. (2024). Contact lens sensor for ocular inflammation monitoring. Biosensors and Bioelectronics, 249, 116003. https://doi.org/10.1016/j.bios.2024.116003
Vancouver
Shi Y, Wang L, Hu Y, Zhang Y, Le W, Liu G, et al. Contact lens sensor for ocular inflammation monitoring. Biosensors and Bioelectronics. 2024;249:116003. doi:10.1016/j.bios.2024.116003
BibTeX
@article{Shi2024,
author = {Shi, Yuqi and Wang, Lin and Hu, Yubing and Zhang, Yihan and Le, Wenhao and Liu, Guohui and Tomaschek, Michael and Jiang, Nan and Yetisen, Ali K},
title = {Contact lens sensor for ocular inflammation monitoring},
journal = {Biosensors and Bioelectronics},
year = {2024},
volume = {249},
pages = {116003},
doi = {10.1016/j.bios.2024.116003}
}
EUVIMED