EUVIMEDEUVIMED entdecken
Crossref

Metal-enhanced fluorescence biosensor integrated in capillary flow-driven microfluidic cartridge for highly sensitive immunoassays

Shine Augustine, Mottour Vinayagam Chinnamani, Chae Won Mun, Jeong-Yong Shin, Tran Quang Trung, Seok Ju Hong, Lai Thi Ngoc Huyen, Eung Hyuk Lee, Soo Hyun Lee, Jong-Joo Rha, Sunghoon Jung, Yunjong Lee und 2 weitere

Biosensors and Bioelectronics · 2024-03 · 248 · 115987

DOI: 10.1016/j.bios.2023.115987 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-03. Verfasst von Shine Augustine und 13 weiteren Autor:innen. Beteiligte Einrichtung: School of Advanced Materials Science & Engineering, Sungkyunkwan University, Suwon, Gyeonggi-do, 16419, Republic of Korea. Hauptthemen laut MEDLINE: Biosensing Techniques, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: Sungkyunkwan University College of Natural Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Point-of-care testing (POCT) for low-concentration protein biomarkers remains challenging due to limitations in biosensor sensitivity and platform integration. This study addresses this gap by presenting a novel approach that integrates a metal-enhanced fluorescence (MEF) biosensor within a capillary flow-driven microfluidic cartridge (CFMC) for the ultrasensitive detection of the Parkinson's disease biomarker, aminoacyl-tRNA synthetase complex interacting multi-functional protein 2 (AIMP-2). Crucial point to this approach is the orientation-controlled immobilization of capture antibody on a nanodimple-structured MEF substrate within the CFMC. This strategy significantly enhances fluorescence signals without quenching, enabling accurate quantification of low-concentration AIMP-2 using a simple digital fluorescence microscope with a light-emitting diode excitation source and a digital camera. The resulting platform exhibits exceptional sensitivity, achieving a limit of detection in the pg/mL range for AIMP-2 in human serum. Additionally, the CFMC design incorporates a capillary-driven passive sample transport mechanism, eliminating the need for external pumps and further simplifying the detection process. Overall, this work demonstrates the successful integration of MEF biosensing with capillary microfluidics for point-of-care applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesMicrofluidic Analytical TechniquesHumansMicrofluidicsImmunoassayBiomarkersGold

Stichwörter der Autor:innen

AIMP-2Capillary flow-driven microfluidic cartridgeGold nanodimpleImmunosandwiching assayMetal-enhanced fluorescencePOCT

Substanzen

BiomarkersGold

Autor:innen und Institutionen

  • School of Advanced Materials Science & Engineering, Sungkyunkwan University, Suwon, Gyeonggi-do, 16419, Republic of Korea.
  • Nano-Bio Convergence Department, Korea Institute of Materials Science (KIMS), Changwon, 51508, Republic of Korea.
  • Division of Pharmacology, Department of Molecular Cell Biology, Samsung, Biomedical Research Institute, Sungkyunkwan University School of Medicine, Suwon, Gyeonggi-do, 16419, Republic of Korea.
  • SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon, Gyeonggi-do, 16419, Republic of Korea.
  • Nano-Bio Convergence Department, Korea Institute of Materials Science (KIMS), Changwon, 51508, Republic of Korea. Electronic address: sgpark@kims.re.kr.
  • School of Advanced Materials Science & Engineering, Sungkyunkwan University, Suwon, Gyeonggi-do, 16419, Republic of Korea; SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon, Gyeonggi-do,…

Förderung

  • Sungkyunkwan University College of Natural Science

Zitieren

APA

Augustine, S., Chinnamani, M. V., Mun, C. W., Shin, J. Y., Trung, T. Q., Hong, S. J., Huyen, L. T. N., Lee, E. H., Lee, S. H., Rha, J. J., Jung, S., Lee, Y., Park, S. G., & Lee, N. E. (2024). Metal-enhanced fluorescence biosensor integrated in capillary flow-driven microfluidic cartridge for highly sensitive immunoassays. Biosensors and Bioelectronics, 248, 115987. https://doi.org/10.1016/j.bios.2023.115987

Vancouver

Augustine S, Chinnamani MV, Mun CW, Shin JY, Trung TQ, Hong SJ, et al. Metal-enhanced fluorescence biosensor integrated in capillary flow-driven microfluidic cartridge for highly sensitive immunoassays. Biosensors and Bioelectronics. 2024;248:115987. doi:10.1016/j.bios.2023.115987

BibTeX
@article{Augustine2024,
  author = {Augustine, Shine and Chinnamani, Mottour Vinayagam and Mun, Chae Won and Shin, Jeong-Yong and Trung, Tran Quang and Hong, Seok Ju and Huyen, Lai Thi Ngoc and Lee, Eung Hyuk and Lee, Soo Hyun and Rha, Jong-Joo and Jung, Sunghoon and Lee, Yunjong and Park, Sung-Gyu and Lee, Nae-Eung},
  title = {Metal-enhanced fluorescence biosensor integrated in capillary flow-driven microfluidic cartridge for highly sensitive immunoassays},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {248},
  pages = {115987},
  doi = {10.1016/j.bios.2023.115987}
}
Kostenlos starten →