EUVIMEDEUVIMED entdecken
Crossref

A self-driven, microfluidic, integrated-circuit biosensing chip for detecting four cardiovascular disease biomarkers

Pei-Rong Li, Sasi Kiran Boilla, Chih-Hung Wang, Pei-Chien Lin, Chien-Nan Kuo, Tsung-Heng Tsai, Gwo-Bin Lee

Biosensors and Bioelectronics · 2024

DOI: 10.1016/j.bios.2023.115931 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Pei-Rong Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan. Hauptthemen laut MEDLINE: Cardiovascular Diseases, Biosensing Techniques. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 47 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiovascular diseases (CVDs) claimed the lives of nearly 21 million people worldwide in 2021, accounting for 30% of global deaths. However, one in five CVD patients is unaware that they have the disease, emphasizing the need for accurate biomarker monitoring. Herein we developed an integrated microfluidic system (IMS) for rapid quantification of four CVD biomarkers, including N-terminal pro B-type natriuretic peptide (NT-proBNP), fibrinogen, cardiac troponin I (cTnI), and C-reactive protein (CRP)- via aptamer-coated interdigitated electrodes (IDE) with integrated circuits (IC) and a self-driven IMS for sample treatment. The device was composed of plasma filtration, metering, and fluidic delay modules, and the former could extract 45% of plasma from a 20-μL blood sample; the metering module could quantify 5 μL of plasma within 90 s. Subsequently, the plasma was transported to a detection chamber, where IC-based IDE sensors made measurements within 5 min. The entire 15-min process allowed us to evaluate biomarkers across a wide dynamic range: NT-proBNP (0.1-10,000 pg/mL), fibrinogen (50-1,000 mg/dL), cTnI (0.1-10,000 pg/mL), and CRP (0.5-9 mg/L). Given that spiked blood samples were measured with reasonable accuracy (>80%), the IMS could see utility in CVD risk assessment and personalized medicine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiovascular DiseasesBiosensing TechniquesHumansMicrofluidicsBiomarkersNatriuretic Peptide, BrainC-Reactive ProteinFibrinogenPeptide Fragments

Stichwörter der Autor:innen

BiomarkerCapillary microfluidicsCardiovascular diseaseIntegrated circuitsInterdigitated electrodesMeteringPlasma isolation

Substanzen

BiomarkersNatriuretic Peptide, BrainC-Reactive ProteinFibrinogenPeptide Fragments

Autor:innen und Institutionen

  • Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan.
  • Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu, 30013, Taiwan.
  • Department of Electronic Engineering, National Chung Cheng University, Chiayi, 62102, Taiwan.
  • Institute of Electronics, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan.
  • Industry Academy Innovation School, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan. Electronic address: henrytsai@nycu.edu.tw.
  • Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan; Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu, 30013, Taiwan. Electronic address…

Zitieren

APA

Li, P. R., Kiran Boilla, S., Wang, C. H., Lin, P. C., Kuo, C. N., Tsai, T. H., & Lee, G. B. (2024). A self-driven, microfluidic, integrated-circuit biosensing chip for detecting four cardiovascular disease biomarkers. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2023.115931

Vancouver

Li PR, Kiran Boilla S, Wang CH, Lin PC, Kuo CN, Tsai TH, et al. A self-driven, microfluidic, integrated-circuit biosensing chip for detecting four cardiovascular disease biomarkers. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2023.115931

BibTeX
@article{Li2024,
  author = {Li, Pei-Rong and Kiran Boilla, Sasi and Wang, Chih-Hung and Lin, Pei-Chien and Kuo, Chien-Nan and Tsai, Tsung-Heng and Lee, Gwo-Bin},
  title = {A self-driven, microfluidic, integrated-circuit biosensing chip for detecting four cardiovascular disease biomarkers},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  doi = {10.1016/j.bios.2023.115931}
}
Kostenlos starten →