EUVIMEDEUVIMED entdecken
Crossref

A wearable and flexible lactic-acid/O2 biofuel cell with an enhanced air-breathing biocathode

Zepeng Kang, Yuanming Wang, Haiyan Song, Xueli Wang, Yi-Heng P Job Zhang, Zhiguang Zhu

Biosensors and Bioelectronics · 2024-02 · 246 · 115845

DOI: 10.1016/j.bios.2023.115845 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-02. Verfasst von Zepeng Kang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Engineering Biology for Low-carbon Manufacturing, Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences, 32 We…. Hauptthemen laut MEDLINE: Bioelectric Energy Sources, Biosensing Techniques, Wearable Electronic Devices. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The performance of biocathode in an enzymatic biofuel cell (EBFC) in the real application is somehow overlooked. Herein, a wearable and flexible lactic-acid/O2 EBFC enhanced with an air-breathing biocathode is designed to solve the limitation of biocathode that arises from the low solubility and slow mass transfer of the dissolved oxygen. To improve the oxygen supply efficiency for the air-breathing biocathode, a superhydrophobic base electrode creating an efficient air-solid-liquid triphase interface is developed. The designed EBFC with an 'island-bridge' configuration is integrated by assembling the current collectors of air-breathing biocathode and bioanode on a commercial laminating film (LF) screen-printed with a noninterfering circuit. It is found that the biocathode/bioanode area ratio should exceed 9:1 so that the designed EBFC (1A//9C) can achieve the optimal performance. This EBFC delivers an open circuit voltage of ca. 0.75 V and outputs a maximum power density of ca. 1.78 mW cm-2. In addition, a scaled-up EBFC (total bioanode area: 1.5 cm2) successfully powers a self-developed low-power device of heartrate in the pulse operation mode when applied on a volunteer's arm.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bioelectric Energy SourcesBiosensing TechniquesWearable Electronic DevicesHumansOxygenElectrodesGlucoseEnzymes, Immobilized

Stichwörter der Autor:innen

Air-breathing biocathodeBioelectrodeTriphase interfaceWearable and flexible enzymatic biofuel cell

Substanzen

OxygenGlucoseEnzymes, Immobilized

Autor:innen und Institutionen

  • Key Laboratory of Engineering Biology for Low-carbon Manufacturing, Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences, 32 West 7th Avenue, Tianjin Airport Economic Area, Tianjin 300308, PR China…
  • National Human Genetic Resources Center, Beijing 102206, PR China.

Zitieren

APA

Kang, Z., Wang, Y., Song, H., Wang, X., Zhang, Y. P. J., & Zhu, Z. (2024). A wearable and flexible lactic-acid/O2 biofuel cell with an enhanced air-breathing biocathode. Biosensors and Bioelectronics, 246, 115845. https://doi.org/10.1016/j.bios.2023.115845

Vancouver

Kang Z, Wang Y, Song H, Wang X, Zhang YPJ, Zhu Z. A wearable and flexible lactic-acid/O2 biofuel cell with an enhanced air-breathing biocathode. Biosensors and Bioelectronics. 2024;246:115845. doi:10.1016/j.bios.2023.115845

BibTeX
@article{Kang2024,
  author = {Kang, Zepeng and Wang, Yuanming and Song, Haiyan and Wang, Xueli and Zhang, Yi-Heng P Job and Zhu, Zhiguang},
  title = {A wearable and flexible lactic-acid/O2 biofuel cell with an enhanced air-breathing biocathode},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {246},
  pages = {115845},
  doi = {10.1016/j.bios.2023.115845}
}
Kostenlos starten →