EUVIMEDEUVIMED entdecken
Crossref

DNA four-way junction-driven dual-rolling circle amplification sandwich-type aptasensor for ultra-sensitive and specific detection of tumor-derived exosomes

Zhuyang Zhao, Sha Yang, Xiaoqi Tang, Liu Feng, Zishan Ding, Zhiguo Chen, Xing Luo, Ruijia Deng, Jing Sheng, Shuang Xie, Kai Chang, Ming Chen

Biosensors and Bioelectronics · 2024

DOI: 10.1016/j.bios.2023.115841 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Zhuyang Zhao und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory Medicine, Southwest Hospital, Army Medical University (Third Military Medical University), 30 Gaotanyan, Shapingba …. Hauptthemen laut MEDLINE: Exosomes, Aptamers, Nucleotide, Biosensing Techniques, Metal Nanoparticles. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 72 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

There is an urgent need to accurately quantify tumor-derived exosomes, which have emerged as promising non-invasive tumor diagnostic biomarkers. Herein, a bispecific-aptamer sandwich-type gold nanoparticle-modified electrochemical aptasensor was developed based on a four-way junction (4-WJ)-triggered dual rolling circle amplification (RCA)-assisted methylene blue (MB)/G-quadruplex strategy for extremely specific and sensitive exosome detection. This aptamer/exosome/aptamer sandwich-type design contained a CD63-specific aptamer and a cancerous mucin-1 (MUC1) protein-specific aptamer. The CD63 aptamer modified on a gold electrode captured exosomes, and then the sandwich-type aptasensor was formed with the addition of the MUC1 aptamer. The MUC1 aptamer's 3'-end sequence facilitated the formation of 4-WJ, assisted by a molecular beacon probe and a binary DNA probe. Subsequently, a dual-RCA reaction was triggered by binding to two cytosine-rich circle DNA templates at both ends of 4-WJ. Ultimately, dual-RCA products containing multiple G-quadruplex conformations were generated with the assistance of K+ to trap abundant MB indicators and amplify electrochemical signals. The aptasensor exhibited high specificity, sensitivity, repeatability, and stability toward MCF-7-derived exosomes, with a detection limit of 20 particles/mL and a linear range of 1 × 102 to 1 × 107 particles/mL. Moreover, it showed excellent applicability in clinical settings to recover exosomes in normal human serum. Our aptasensor is anticipated to serve as a versatile platform for detecting various specific aptamer-based targets in biomedical and bioanalytical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ExosomesAptamers, NucleotideBiosensing TechniquesMetal NanoparticlesNeoplasmsHumansGoldLimit of DetectionElectrochemical TechniquesDNA

Stichwörter der Autor:innen

DNA four-way junction (4-WJ)Exosome detectionG-quadruplexRolling circle amplification (RCA)Sandwich-type electrochemical aptasensor

Substanzen

GoldAptamers, NucleotideDNA

Autor:innen und Institutionen

  • Department of Clinical Laboratory Medicine, Southwest Hospital, Army Medical University (Third Military Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China.
  • Department of Clinical Laboratory Medicine, Southwest Hospital, Army Medical University (Third Military Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China. Electronic address: changkai0203@t…
  • Department of Clinical Laboratory Medicine, Southwest Hospital, Army Medical University (Third Military Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China; College of Pharmacy and Laboratory…

Zitieren

APA

Zhao, Z., Yang, S., Tang, X., Feng, L., Ding, Z., Chen, Z., Luo, X., Deng, R., Sheng, J., Xie, S., Chang, K., & Chen, M. (2024). DNA four-way junction-driven dual-rolling circle amplification sandwich-type aptasensor for ultra-sensitive and specific detection of tumor-derived exosomes. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2023.115841

Vancouver

Zhao Z, Yang S, Tang X, Feng L, Ding Z, Chen Z, et al. DNA four-way junction-driven dual-rolling circle amplification sandwich-type aptasensor for ultra-sensitive and specific detection of tumor-derived exosomes. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2023.115841

BibTeX
@article{Zhao2024,
  author = {Zhao, Zhuyang and Yang, Sha and Tang, Xiaoqi and Feng, Liu and Ding, Zishan and Chen, Zhiguo and Luo, Xing and Deng, Ruijia and Sheng, Jing and Xie, Shuang and Chang, Kai and Chen, Ming},
  title = {DNA four-way junction-driven dual-rolling circle amplification sandwich-type aptasensor for ultra-sensitive and specific detection of tumor-derived exosomes},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  doi = {10.1016/j.bios.2023.115841}
}
Kostenlos starten →