EUVIMEDEUVIMED entdecken
Crossref

Rapid and simultaneous multiple detection of a tripledemic using a dual-gate oxide semiconductor thin-film transistor-based immunosensor

Sehun Jeong, Seong Uk Son, Jingyu Kim, Seong-In Cho, Taejoon Kang, Sunjoo Kim, Eun-Kyung Lim, Sang-Hee Ko Park

Biosensors and Bioelectronics · 2023

DOI: 10.1016/j.bios.2023.115700 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023. Verfasst von Sehun Jeong und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Repub…. Hauptthemen laut MEDLINE: Biosensing Techniques, SARS-CoV-2, COVID-19, Influenza, Human. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 73 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The simultaneous infection with a tripledemic-simultaneous infection with influenza A pH1N1 virus (Flu), severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), and respiratory syncytial virus (RSV)-necessitates the development of accurate and fast multiplex diagnostic tests. The coronavirus disease 2019 (COVID-19) pandemic has emphasized the importance of virus detection. Field-effect transistor (FET)-based immuno-biosensors have a short detection time and do not require labeling or polymerase chain reaction. This study demonstrates the rapid, sensitive detection of influenza A pH1N1, SARS-CoV-2, and RSV using a multiplex immunosensor based on a dual-gate oxide semiconductor thin-film transistor (TFT), a type of FET. The dual-gate oxide TFT was modified by adjusting both top and bottom gate insulators to improve capacitive coupling to approximately 120-fold amplification, exhibiting a high pH sensitivity of about 10 V/pH. The dual-gate oxide TFT-based immunosensor detected the target proteins (hemagglutinin (HA) protein of Flu, spike 1 (S1) protein of SARS-CoV-2, and fusion protein of RSV) of each virus, with a limit of detection of approximately 1 fg/mL. Cultured viruses in phosphate-buffered saline or artificial saliva and clinical nasopharynx samples were detected in 1-μL sample volumes within 60 s. This promising diagnosis could be potentially as point-of-care tests to facilitate a prompt response to future pandemics with high sensitivity and multiplexed detection without pretreatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesSARS-CoV-2COVID-19Influenza, HumanInfluenza A Virus, H1N1 SubtypeRespiratory Syncytial Virus InfectionsHumansTransistors, ElectronicImmunoassaySemiconductorsLimit of DetectionEquipment DesignOxidesRespiratory Syncytial Viruses

Stichwörter der Autor:innen

Dual-gate thin-film transistorMultiple detectionPoint-of-care testTripledemic

Substanzen

Oxides

Autor:innen und Institutionen

  • Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • BioNanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology, 125 Gwahak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea; Department of Nanobiotechnology, Korea Research Institute of Bio…
  • BioNanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology, 125 Gwahak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea; School of Pharmacy, Sungkyunkwan University, Suwon, 16419, Repub…
  • Department of Laboratory Medicine, Gyeongsang National University Changwon Hospital, Changwon, 51472, Republic of Korea; Gyeongnam Center for Infectious Disease Control and Prevention, Changwon, 51154, Republic of Korea…
  • Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea. Electronic address: shkp@kaist.ac.kr.

Zitieren

APA

Jeong, S., Son, S. U., Kim, J., Cho, S. I., Kang, T., Kim, S., Lim, E. K., & Ko Park, S. H. (2023). Rapid and simultaneous multiple detection of a tripledemic using a dual-gate oxide semiconductor thin-film transistor-based immunosensor. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2023.115700

Vancouver

Jeong S, Son SU, Kim J, Cho SI, Kang T, Kim S, et al. Rapid and simultaneous multiple detection of a tripledemic using a dual-gate oxide semiconductor thin-film transistor-based immunosensor. Biosensors and Bioelectronics. 2023. doi:10.1016/j.bios.2023.115700

BibTeX
@article{Jeong2023,
  author = {Jeong, Sehun and Son, Seong Uk and Kim, Jingyu and Cho, Seong-In and Kang, Taejoon and Kim, Sunjoo and Lim, Eun-Kyung and Ko Park, Sang-Hee},
  title = {Rapid and simultaneous multiple detection of a tripledemic using a dual-gate oxide semiconductor thin-film transistor-based immunosensor},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  doi = {10.1016/j.bios.2023.115700}
}
Kostenlos starten →