Toll-like receptor-immobilized carbon paste electrodes with plasma functionalized amine termination: Towards real-time electrochemical based triaging of gram-negative bacteria
Biosensors and Bioelectronics · 2023
DOI: 10.1016/j.bios.2023.115674 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023. Verfasst von Rahul Gangwar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Indian Institute of Technology Hyderabad, 502284, India. Electronic address: ee18resch11019@iith.ac.in. Hauptthemen laut MEDLINE: Biosensing Techniques, Escherichia coli, Electrochemical Techniques, Toll-Like Receptor 4. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 75 Literaturangaben. Gefördert von: Ministry of Higher Education, Malaysia, Department of Science and Technology, Ministry of Science and Technology, India.
Abstract (Originalsprache)
Chronic wounds caused due to bacterial biofilms are detrimental to a patient, and an immediate diagnosis of these bacteria can aid in an effective treatment, which is still an unmet clinical need. An instant and accurate identification of bacterial type could be made by utilizing the Toll-Like Receptors (TLRs) combined with Myeloid Differentiation factor 2 (MD-2). Given this, we have developed an electrochemical sensing platform to identify the gram-negative (gram-ve) bacteria using TLR4/MD-2 complex. The nonthermal plasma (NTP) technique was utilized to functionalize amine groups onto the carbon surface to fabricate cost-effective carbon paste working electrodes (CPEs). The proposed electrochemical sensor platform with a specially engineered electrochemical cell (E-Cell) identified the Escherichia coli (E. coli) in a wide linear range of 1.5×10° - 1.5×106 C.F.U./mL, accounting for a very low detection limit of 0.087 C.F.U./mL. The novel and cost-effective sensor platform identified gram-ve bacteria predominantly in a mixture of gram positive (gram+ve) bacteria and fungi. Further, towards real-time detection of bacteria and point-of-care (PoC) applications, the effect of the pond water matrix was studied, which was minimal, and the sensor could identify E. coli concentrations selectively, showing the potential application of the proposed platform towards real-time bacterial detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electrical Engineering, Indian Institute of Technology Hyderabad, 502284, India. Electronic address: ee18resch11019@iith.ac.in.
- Department of Chemistry, Indian Institute of Technology Hyderabad, 502284, India; Department of Chemistry, The Chinese University of Hong Kong, Shatin, NT, Hong Kong Special Administrative Region of China. Electronic ad…
- Department of Biomedical Engineering, Indian Institute of Technology Hyderabad, 502284, India. Electronic address: bm19resch12001@iith.ac.in.
- Department of Chemistry, Indian Institute of Technology Hyderabad, 502284, India. Electronic address: csubbu@chy.iith.ac.in.
- Department of Biomedical Engineering, Indian Institute of Technology Hyderabad, 502284, India. Electronic address: aravind@bme.iith.ac.in.
- Department of Electrical Engineering, Indian Institute of Technology Hyderabad, 502284, India. Electronic address: svanjari@ee.iith.ac.in.
Förderung
- Ministry of Higher Education, Malaysia
- Department of Science and Technology, Ministry of Science and Technology, India
Zitieren
APA
Gangwar, R., Ray, D., Khatun, S., Subrahmanyam, C., Rengan, A. K., & Vanjari, S. R. K. (2023). Toll-like receptor-immobilized carbon paste electrodes with plasma functionalized amine termination: Towards real-time electrochemical based triaging of gram-negative bacteria. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2023.115674
Vancouver
Gangwar R, Ray D, Khatun S, Subrahmanyam C, Rengan AK, Vanjari SRK. Toll-like receptor-immobilized carbon paste electrodes with plasma functionalized amine termination: Towards real-time electrochemical based triaging of gram-negative bacteria. Biosensors and Bioelectronics. 2023. doi:10.1016/j.bios.2023.115674
BibTeX
@article{Gangwar2023,
author = {Gangwar, Rahul and Ray, Debjyoti and Khatun, Sajmina and Subrahmanyam, Challapalli and Rengan, Aravind Kumar and Vanjari, Siva Rama Krishna},
title = {Toll-like receptor-immobilized carbon paste electrodes with plasma functionalized amine termination: Towards real-time electrochemical based triaging of gram-negative bacteria},
journal = {Biosensors and Bioelectronics},
year = {2023},
doi = {10.1016/j.bios.2023.115674}
}
EUVIMED