The Construction and Mechanism of SPCE/Cu 2 O@MWCNTs Electrochemical Sensor for Menthone Detection for Epileptic Seizures Prediction
Advanced Healthcare Materials · 2025
DOI: 10.1002/adhm.202500764 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2025. Verfasst von Zilong Hu und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronic and Information Engineering, Liaoning Technical University, Huludao, 125105, China. Hauptthemen laut MEDLINE: Copper, Nanotubes, Carbon, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: JSPS KAKENHI, Brainclos Corp., Key Technologies Research and Development Program of Guangzhou Municipality.
Abstract (Originalsprache)
Prediction of seizures is critical for the effective management and treatment of epileptic disorders. The epileptic patients generates certain biomarker before the occurance of seizure, which are considered as the potential biomarkers for prediction. However, research on the detection of these biomarkers remains limited, and the detection process is still challenging. Herein, an electrochemical sensor for detecting menthone, a biomarker associated with epilepstic seizure is reported. The menthone electrochemical sensor is based on the screen‐printed carbon electrode (SPCE) modified with a Cu 2 O@MWCNTs nanomaterial. The electrode exhibits the detection limit of 0.3 m M and the sensitivity of 88.243 µA·m M ⁻ 1 ·cm⁻ 2 . Additionally, the SPCE/Cu 2 O@MWCNTs electrode demonstrates a good linearship with menthone concentration in phosphate buffered saline (PBS). Cell assay results further confirm the excellent biocompatibility of the SPCE/Cu 2 O@MWCNTs electrode, highlighting its potential for its utilization in the real biosamples. Through the mechanism study, the reaction mechanism between menthone and the sensing material is proposed. This electrode not only provides a reliable and cost‐effective method for predicting epileptic seizures, thus paving the way for advancements in electrochemical biosensing technologies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Electronic and Information Engineering, Liaoning Technical University, Huludao, 125105, China.
- Research Center for Medical Artificial Intelligence, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518000, China.
- Research Institute of Advanced Materials (Shenzhen) Co., Ltd, Shenzhen, 518000, China.
- Institut für Physik, Institut für Chemie, Center for the Science of Materials Berlin, Humboldt-Universität zu Berlin, 12489, Berlin, Germany.
- School of Biomedical Engineering, Capital Medical University, Beijing, 100069, China.
- Faculty of Biomedical Engineering, Shenzhen University of Advanced Technology, Shenzhen, 518000, China.
ORCID-Profile: Liangtao Yang, Wendong Yang
Förderung
- JSPS KAKENHI
- Brainclos Corp.
- Key Technologies Research and Development Program of Guangzhou Municipality
- Shenzhen Science and Technology Innovation Program
Zitieren
APA
Hu, Z., Yang, L., Yang, W., Han, J., Li, C., Liu, Q., Xiang, Z., & Wu, J. (2025). The Construction and Mechanism of SPCE/Cu 2 O@MWCNTs Electrochemical Sensor for Menthone Detection for Epileptic Seizures Prediction. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202500764
Vancouver
Hu Z, Yang L, Yang W, Han J, Li C, Liu Q, et al. The Construction and Mechanism of SPCE/Cu 2 O@MWCNTs Electrochemical Sensor for Menthone Detection for Epileptic Seizures Prediction. Advanced Healthcare Materials. 2025. doi:10.1002/adhm.202500764
BibTeX
@article{Hu2025,
author = {Hu, Zilong and Yang, Liangtao and Yang, Wendong and Han, Jie and Li, Chunlin and Liu, Qing and Xiang, Zhengchen and Wu, Jinglong},
title = {The Construction and Mechanism of SPCE/Cu 2 O@MWCNTs Electrochemical Sensor for Menthone Detection for Epileptic Seizures Prediction},
journal = {Advanced Healthcare Materials},
year = {2025},
doi = {10.1002/adhm.202500764}
}