EUVIMEDEUVIMED entdecken
Crossref

A ratiometric fluorescent paper sensor based on dye-embedded MOF for high-sensitive detection of arginine

Jie Chi, Yanyan Song, Liang Feng

Biosensors and Bioelectronics · 2023-12 · 241 · 115666

DOI: 10.1016/j.bios.2023.115666 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-12. Verfasst von Jie Chi und 2 weiteren Autor:innen. Beteiligte Einrichtung: College of Sciences, Northeastern University, Shenyang, 110819, China; Department of Instrumentation and Analytical Chemistry, CAS Key Laboratory of …. Hauptthemen laut MEDLINE: Arginine, Biosensing Techniques, Fluorescent Dyes, Metal-Organic Frameworks. Die Arbeit wurde bisher 123-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: Chinese Academy of Sciences, Northeastern University, Dalian National Laboratory for Clean Energy.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ratiometric fluorescent sensors can suppress the interference of factors unrelated to analysis due to their built-in self-calibration characteristics, which exhibit higher sensitivity and more obvious visual detection in the process of qualitative and quantitative analysis. Herein, we constructed a ratiometric fluorescence probe based on fluorescent/colorimetric dual-mode method for the determination of arginine by encapsulating rhodamine B in-situ into UiO-66-NH2 MOFs (UiO-66-NH2@RhB). The as-prepared probe showed dual-emission characteristics under a single excitation wavelength. The fluorescence intensity of UiO-66-NH2 was increased significantly by arginine, while the emission peak intensity of rhodamine B remained stable, resulting in a single-signal response with fixed reference. Furthermore, the practicality of the presented sensor was successfully validated by quantitative detection of arginine in human serum. More significantly, paper-based sensors for arginine detection were devised by using carboxymethyl cellulose modified filter papers. Under the irradiation of ultraviolet light, the paper-based sensors would produce obvious color variation from lightpink to bluish violet. This work provided a convenient and efficient method for on-site detection of arginine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArginineBiosensing TechniquesFluorescent DyesMetal-Organic FrameworksHumansRhodaminesPaperColorimetryLimit of DetectionSpectrometry, Fluorescence

Stichwörter der Autor:innen

Arginine detectionMetal–organic frameworkPaper-based sensorRatiometric fluorescenceSensitivity

Substanzen

ArginineFluorescent DyesRhodaminesrhodamine BMetal-Organic Frameworks

Autor:innen und Institutionen

  • College of Sciences, Northeastern University, Shenyang, 110819, China; Department of Instrumentation and Analytical Chemistry, CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemi…
  • College of Sciences, Northeastern University, Shenyang, 110819, China. Electronic address: yysong@mail.neu.edu.cn.
  • Department of Instrumentation and Analytical Chemistry, CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 1…

Förderung

  • Chinese Academy of Sciences
  • Northeastern University
  • Dalian National Laboratory for Clean Energy
  • National Natural Science Foundation of China

Zitieren

APA

Chi, J., Song, Y., & Feng, L. (2023). A ratiometric fluorescent paper sensor based on dye-embedded MOF for high-sensitive detection of arginine. Biosensors and Bioelectronics, 241, 115666. https://doi.org/10.1016/j.bios.2023.115666

Vancouver

Chi J, Song Y, Feng L. A ratiometric fluorescent paper sensor based on dye-embedded MOF for high-sensitive detection of arginine. Biosensors and Bioelectronics. 2023;241:115666. doi:10.1016/j.bios.2023.115666

BibTeX
@article{Chi2023,
  author = {Chi, Jie and Song, Yanyan and Feng, Liang},
  title = {A ratiometric fluorescent paper sensor based on dye-embedded MOF for high-sensitive detection of arginine},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  volume = {241},
  pages = {115666},
  doi = {10.1016/j.bios.2023.115666}
}
Kostenlos starten →