EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Comparative visible-light and near-infrared fluorescence detection of microRNA in blood plasma with paper lateral flow test strips

Xuefei Gao, Yingjie Hang, Jennifer Boryczka, Weirui Tan, Peng Zheng, Feng Yang, Elizabeth Engler-Chiurazzi, James W Simpkins, Nianqiang Wu

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2025.117903 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Xuefei Gao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, WV, 26506-6106, United States. Hauptthemen laut MEDLINE: MicroRNAs, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAID NIH HHS, National Institute of Allergy and Infectious Diseases, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Prevailing colorimetric paper lateral flow strips (PLFSs) are inexpensive and easy to use by untrained personnel, but suffer from low sensitivity and severe interference from complex sample matrices such as blood plasma. Hence, a PLFS based on near-infrared fluorescence (NIRF) has been developed to directly detect microRNA (miRNA) in blood plasma without any further sample pretreatment. To mitigate the issue of low intensity and photo-instability of organic NIRF dye molecules, the dye-encapsulated silica nanoparticles have been synthesized and incorporated into a PLFS for miRNA detection. To demonstrate the advantage of NIRF, a PLFS based on visible-light fluorescence (VisF) has also been constructed as the control. The test results reveal that the NIRF-PLFS with fluorescence emission at 773 nm exhibits sensing performance comparable to the VisF-PLFS with fluorescence emission at 542 nm when measuring miRNA in buffer solution. However, the NIRF-PLFS shows far superior performance over the VisF-PLFS in terms of the linear detection range and the limit of detection when measuring miRNA in blood plasma samples. The NIRF-PLFS has achieved a limit of detection of 50 pM toward miRNA in the diluted blood plasma sample, two orders of magnitude lower than that of the VisF-PLFS. The developed NIRF-PLFS exhibits great potential as a point-of-care (POC) tool in detection of disease biomarkers in human fluid samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroRNAsBiosensing TechniquesHumansLimit of DetectionSilicon DioxidePaperNanoparticlesFluorescent DyesSpectrometry, FluorescenceLightColorimetryReagent StripsFluorescenceSpectroscopy, Near-Infrared

Stichwörter der Autor:innen

BiomarkerBlood testsNear-infrared fluorescencePaper-based lateral flow test stripmiRNA

Substanzen

MicroRNAsSilicon DioxideFluorescent DyesReagent Strips

Autor:innen und Institutionen

  • Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, WV, 26506-6106, United States.
  • Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, MA, 01003-9303, United States.
  • Industrial and Management Systems Engineering Department, West Virginia University, Morgantown, WV, 26506, United States.
  • Department of Neuroscience, Center for Basic and Translational Stroke Research, Center for Neuroscience, Morgantown, WV, 26505, United States.
  • Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, WV, 26506-6106, United States; Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, MA, 01003-9303,…

Förderung

  • NIAID NIH HHS
  • National Institute of Allergy and Infectious Diseases
  • National Institutes of Health
  • National Institute on Drug Abuse

Zitieren

APA

Gao, X., Hang, Y., Boryczka, J., Tan, W., Zheng, P., Yang, F., Engler-Chiurazzi, E., Simpkins, J. W., & Wu, N. (2025). Comparative visible-light and near-infrared fluorescence detection of microRNA in blood plasma with paper lateral flow test strips. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117903

Vancouver

Gao X, Hang Y, Boryczka J, Tan W, Zheng P, Yang F, et al. Comparative visible-light and near-infrared fluorescence detection of microRNA in blood plasma with paper lateral flow test strips. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117903

BibTeX
@article{Gao2025,
  author = {Gao, Xuefei and Hang, Yingjie and Boryczka, Jennifer and Tan, Weirui and Zheng, Peng and Yang, Feng and Engler-Chiurazzi, Elizabeth and Simpkins, James W and Wu, Nianqiang},
  title = {Comparative visible-light and near-infrared fluorescence detection of microRNA in blood plasma with paper lateral flow test strips},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117903}
}
Kostenlos starten →