Fully integrated sample-in-answer-out platform for viral detection using digital reverse transcription recombinase polymerase amplification (dRT-RPA)
Biosensors and Bioelectronics · 2023-10 · 237 · 115487
DOI: 10.1016/j.bios.2023.115487 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-10. Verfasst von Islam Seder und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Technology, Technical University of Denmark, Ørsteds Plads, DK-2800, Kgs. Lyngby, Denmark. Hauptthemen laut MEDLINE: COVID-19, Biosensing Techniques. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Novo Nordisk Fonden.
Abstract (Originalsprache)
Recombinase polymerase amplification (RPA) is one of the most promising diagnostic methods for pathogen detection, owing to the simplified isothermal amplification technique. Using one-step digital reverse transcription RPA (dRT-RPA) to detect viral RNA provides a fast diagnosis and absolute quantification. Here, we present a chip that purifies, digitalizes, and detects viral RNA of SARS-CoV-2 in a fully automated and sensitive manner. The chip purifies the RNA using the surface charge concept of magnet bead-RNA binding, then mixes the RNA with the amplification reagents, digitalizes the amplification mixture, and performs dRT-RPA. RNA-bead complex is transported among purification buffers that are separated by an oil phase. For reagent manipulation and mixing, a magnetic valve system is integrated on the chip, where an external magnet controls the reagent direction and time of addition. Besides, a novel vacuum system is suggested to drive and regulate the reagents into two fluid systems simultaneously in ∼2 min. We also developed a cost-effective way to perform fluorescent detection for dRT-RPA on chip by using EvaGreen® dye. With integrated heating and optical detection system, the on-chip dRT-RPA presents a sample-to-answer detection platform for absolute viral RNA quantitation in 37 min and a sensitivity as low as 10 RNA copies/μL. Hence, this platform is expected to be a useful tool for accurate and automated diagnosis of infectious diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Health Technology, Technical University of Denmark, Ørsteds Plads, DK-2800, Kgs. Lyngby, Denmark.
- Department of Health Technology, Technical University of Denmark, Ørsteds Plads, DK-2800, Kgs. Lyngby, Denmark. Electronic address: suyi@dtu.dk.
Förderung
- Novo Nordisk Fonden
Zitieren
APA
Seder, I., Coronel-Tellez, R., Helalat, S. H., & Sun, Y. (2023). Fully integrated sample-in-answer-out platform for viral detection using digital reverse transcription recombinase polymerase amplification (dRT-RPA). Biosensors and Bioelectronics, 237, 115487. https://doi.org/10.1016/j.bios.2023.115487
Vancouver
Seder I, Coronel-Tellez R, Helalat SH, Sun Y. Fully integrated sample-in-answer-out platform for viral detection using digital reverse transcription recombinase polymerase amplification (dRT-RPA). Biosensors and Bioelectronics. 2023;237:115487. doi:10.1016/j.bios.2023.115487
BibTeX
@article{Seder2023,
author = {Seder, Islam and Coronel-Tellez, Rodrigo and Helalat, Seyed Hossein and Sun, Yi},
title = {Fully integrated sample-in-answer-out platform for viral detection using digital reverse transcription recombinase polymerase amplification (dRT-RPA)},
journal = {Biosensors and Bioelectronics},
year = {2023},
volume = {237},
pages = {115487},
doi = {10.1016/j.bios.2023.115487}
}
EUVIMED