A disposable enzymatic biofuel cell for glucose sensing via short-circuit current
Biosensors and Bioelectronics · 2023-06 · 230 · 115272
DOI: 10.1016/j.bios.2023.115272 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-06. Verfasst von Jannatul Morshed und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Material Science, Faculty of Pure and Applied Science, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-5358, Japan. Hauptthemen laut MEDLINE: Bioelectric Energy Sources, Biosensing Techniques. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: Yashima Environment Technology Foundation, Japan Society for the Promotion of Science, Iketani Science and Technology Foundation.
Abstract (Originalsprache)
It is essential to construct a biofuel cell-based sensor and develop an effective strategy to detect glucose without any potentiostat circuitry in order to create a simple and miniaturized device. In this report, an enzymatic biofuel cell (EBFC) is fabricated by the facile design of an anode and cathode on a screen-printed carbon electrode (SPCE). To construct the anode, thionine and flavin adenine dinucleotide-dependent glucose dehydrogenase (FAD-GDH) are covalently immobilized via a crosslinker to make a cross-linked redox network. As a cathode, the Pt-free oxygen reduction carbon catalyst is employed alternative to the commonly used bilirubin oxidase. We proposed the importance of EBFC-based sensors through the connection of anode and cathode; they can identify a short-circuit current by means of applied zero external voltage, thereby capable of glucose detection without under the operation of the potentiostat. The result shows that the EBFC-based sensor could be able to detect based on a short-circuit current with a wide range of glucose concentrations from 0.28 to 30 mM. Further, an EBFC is employed as a one-compartment model energy harvester with a maximum power density of (36 ± 3) μW cm- 2 in sample volume 5 μL. In addition, the constructed EBFC-based sensor demonstrates that the physiological range of ascorbic acid and uric acid shows no significant effect on the short-circuit current generation. Moreover, this EBFC can be used as a sensor in artificial plasma without losing its performance and thereby used as a disposable test strip in real blood sample analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Material Science, Faculty of Pure and Applied Science, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-5358, Japan.
- Université Grenoble Alpes, TIMC-IMAG/CNRS/INSERM, UMR 5525, F-38000, Grenoble, France.
- Division of Material Science, Faculty of Pure and Applied Science, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-5358, Japan. Electronic address: seiya@ims.tsukuba.ac.jp.
Förderung
- Yashima Environment Technology Foundation
- Japan Society for the Promotion of Science
- Iketani Science and Technology Foundation
Zitieren
APA
Morshed, J., Hossain, M. M., Zebda, A., & Tsujimura, S. (2023). A disposable enzymatic biofuel cell for glucose sensing via short-circuit current. Biosensors and Bioelectronics, 230, 115272. https://doi.org/10.1016/j.bios.2023.115272
Vancouver
Morshed J, Hossain MM, Zebda A, Tsujimura S. A disposable enzymatic biofuel cell for glucose sensing via short-circuit current. Biosensors and Bioelectronics. 2023;230:115272. doi:10.1016/j.bios.2023.115272
BibTeX
@article{Morshed2023,
author = {Morshed, Jannatul and Hossain, Motaher M and Zebda, Abdelkader and Tsujimura, Seiya},
title = {A disposable enzymatic biofuel cell for glucose sensing via short-circuit current},
journal = {Biosensors and Bioelectronics},
year = {2023},
volume = {230},
pages = {115272},
doi = {10.1016/j.bios.2023.115272}
}
EUVIMED