An enhanced dual detection of DMB-labeled sialic acids using high-resolution accurate mass spectrometry and fluorescence detection
BBA Advances · 2025 · 7 · 100152
DOI: 10.1016/j.bbadva.2025.100152 ↗Kurz gefasst
Fachartikel in der Zeitschrift BBA Advances, 2025. Verfasst von Takayuki Omoto und 7 weiteren Autor:innen. Beteiligte Einrichtung: Integrated Glyco-Biomedical Research Center (iGMED), Institute for Glyco-core Research (iGCORE), Nagoya University, Nagoya 464-8601, Japan. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Japan Society for the Promotion of Science, Novartis International AG, NOVARTIS Foundation (Japan) for the Promotion of Science.
Abstract (Originalsprache)
Sialic acids are important glycan components not only in the conformation of the structure but also in functions of many biological activities. Detection methods for sialic acid have been developed, and fluorescent labeling of sialic acids with 1,2-diamino-4,5-methylenedioxybenzene (DMB) is the best method for its analysis. However, identifying and quantifying sialic acids using mass spectrometry (MS) remains difficult because of the diversity of sialic acids, including O-acetylation. In this study, we initially focused on enhancing the liquid chromatography (LC) separation of DMB-labeled sialic acids in bovine submaxillary mucin (BSM). We successfully achieved highly resolutive separation of 14 types of sialic acids, including multiply O-acetylated species, using a CAPCELL CORE C18 column. These structures were subsequently confirmed through collision-induced dissociation (CID) fragmentation. We then assessed MS and fluorescence detection (FLD) sensitivity using Neu5Ac, Neu5Gc, and Kdn standards, determining detection limits of 32 fmol for MS and 320 amol for FLD, with 320 fmol needed for CID-based structural analysis. These findings highlight the complementary nature of fluorescence and mass spectrometry techniques for DMB-labeled sialic acids identification and quantification. We also examined both CID and electron-activated dissociation (EAD) on the ZenoTOF 7600. CID fragment analysis revealed C5-specific diagnostic fragment ions for Neu5Ac, Neu5Gc, and Kdn. EAD spectra predominantly induced fragmentation of the fluorescent DMB core, regardless of applied variable kinetic energies. This study also led to the discovery of a new structure, Neu5Gc7,8,9Ac3, alongside the previously reported Neu5,7,8,9Ac4 in BSM.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Integrated Glyco-Biomedical Research Center (iGMED), Institute for Glyco-core Research (iGCORE), Nagoya University, Nagoya 464-8601, Japan.
- US 41-UAR 2014-PLBS, Université de Lille, CNRS, INSERM, CHU Lille, Institut Pasteur de Lille, Lille, France.
- Graduate School of Bioagricultural Sciences, Nagoya University, Nagoya 464-8601, Japan.
- K.K. ABSciex Japan, Shinagawa Tokyo, 140-0001, Japan.
Förderung
- Japan Society for the Promotion of Science
- Novartis International AG
- NOVARTIS Foundation (Japan) for the Promotion of Science
- Japan Agency for Medical Research and Development
Zitieren
APA
Omoto, T., Yamakawa, N., Wu, D., Mori, H., Takeda, U., Hane, M., Kitajima, K., & Sato, C. (2025). An enhanced dual detection of DMB-labeled sialic acids using high-resolution accurate mass spectrometry and fluorescence detection. BBA Advances, 7, 100152. https://doi.org/10.1016/j.bbadva.2025.100152
Vancouver
Omoto T, Yamakawa N, Wu D, Mori H, Takeda U, Hane M, et al. An enhanced dual detection of DMB-labeled sialic acids using high-resolution accurate mass spectrometry and fluorescence detection. BBA Advances. 2025;7:100152. doi:10.1016/j.bbadva.2025.100152
BibTeX
@article{Omoto2025,
author = {Omoto, Takayuki and Yamakawa, Nao and Wu, Di and Mori, Hitoshi and Takeda, Ushio and Hane, Masaya and Kitajima, Ken and Sato, Chihiro},
title = {An enhanced dual detection of DMB-labeled sialic acids using high-resolution accurate mass spectrometry and fluorescence detection},
journal = {BBA Advances},
year = {2025},
volume = {7},
pages = {100152},
doi = {10.1016/j.bbadva.2025.100152}
}
EUVIMED