Systematic Characterisation of the Fragmentation of Flavonoids Using High-Resolution Accurate Mass Electrospray Tandem Mass Spectrometry

Candy Jiang iD, Paul J Gates iD

Molecules · 06.11.2024 · 29 (22) · 5246

DOI: 10.3390/molecules29225246 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, online erschienen am 06.11.2024. Verfasst von Candy Jiang und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry, University of Bristol, Cantock's Close, Bristol BS8 1TS, UK. Hauptthemen laut MEDLINE: Flavonoids, Tandem Mass Spectrometry, Spectrometry, Mass, Electrospray Ionization. Die Arbeit wurde bisher 63-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flavonoids are a class of polyphenolic secondary metabolites found in plants. Due to their ubiquity in our daily dietary intake and their major anti-oxidative, anti-inflammatory and anti-mutagenic activities, they have been a major focus of wide-ranging research for the past two decades. Mass spectrometry combined with liquid chromatography is one of the most popular techniques for the analysis of flavonoids. In this study, high-resolution accurate mass electrospray tandem mass spectrometry was used to study 30 flavonoids in both positive and negative ionisation modes. From the data obtained, common losses were summarised and compiled. Dominating neutral losses were tabulated. The radical loss of CH3· was observed in flavonoids containing methoxy groups and three key diagnostic product ions were identified. These were m/z 153 (indicative of two OH groups on ring A) m/z 167 (indicative of one OH and one methoxy group on ring A) and m/z 151 (a flavanol, with no ketone oxygen but two OH groups on ring A). These will be useful in structural elucidation of unknown flavonoids and flavonoid metabolites. Energy breakdown graphs were utilised to distinguish between three pairs of structural isomers, and to help rationalise proposed fragmentation pathways. Lastly, a competition of loss of CH3· and methane was reported for rhamnetin and isorhamnetin in the negative ion mode for the first time. Proposed fragmentation pathways were given to rationalise the differences in peak intensities for this competitive process.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FlavonoidsTandem Mass SpectrometrySpectrometry, Mass, Electrospray IonizationMolecular StructureQuercetinChromatography, Liquid

Stichwörter der Autor:innen

flavonoidsfragmentationmass spectrometrystructure characterisation

Substanzen

FlavonoidsQuercetinrhamnetin

Autor:innen und Institutionen

  • School of Chemistry, University of Bristol, Cantock's Close, Bristol BS8 1TS, UK.

ORCID-Profile: Candy Jiang, Paul J Gates

Zitieren

APA

Jiang, C., & Gates, P. J. (2024). Systematic Characterisation of the Fragmentation of Flavonoids Using High-Resolution Accurate Mass Electrospray Tandem Mass Spectrometry. Molecules, 29(22), 5246. https://doi.org/10.3390/molecules29225246

Vancouver

Jiang C, Gates PJ. Systematic Characterisation of the Fragmentation of Flavonoids Using High-Resolution Accurate Mass Electrospray Tandem Mass Spectrometry. Molecules. 2024;29(22):5246. doi:10.3390/molecules29225246

BibTeX
@article{Jiang2024,
  author = {Jiang, Candy and Gates, Paul J},
  title = {Systematic Characterisation of the Fragmentation of Flavonoids Using High-Resolution Accurate Mass Electrospray Tandem Mass Spectrometry},
  journal = {Molecules},
  year = {2024},
  volume = {29},
  number = {22},
  pages = {5246},
  doi = {10.3390/molecules29225246}
}
Kostenlos starten →