Fluoroscopy Time and Radiation Exposure in TEVAR Versus EVAR: A Systematic Review and Meta-Analysis
Annals of Vascular Surgery · 2026
DOI: 10.1016/j.avsg.2026.01.003 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Annals of Vascular Surgery, 2026. Verfasst von Fotios O Efthymiou und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece. Electronic address: fotis_efth@hotmail.gr. Hauptthemen laut MEDLINE: Endovascular Aneurysm Repair, Radiation Exposure, Endovascular Procedures, Radiation Dosage. Die Arbeit nennt 84 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Ionizing radiation exposure is inherent to endovascular surgery and is associated with adverse health effects. This systematic review and meta-analysis compared patient radiation exposure during endovascular aneurysm repair (EVAR) and thoracic endovascular aneurysm repair (TEVAR), focusing on fluoroscopy time (FT), kerma-area product (KAP), and cumulative air kerma (CAK). METHODS: A Preferred Reporting Items for Systematic Reviews and Meta-Analyses-compliant search of MEDLINE, Scopus, and the Cochrane Library (June 2015-June 2025) identified English-language studies with ≥20 patients reporting FT, KAP, or CAK during elective EVAR or TEVAR. Pooled means with 95% confidence intervals were calculated using random-effects modeling. Risk of bias was assessed with ROBINS-I version 2 and publication bias with Egger's test and funnel plots. RESULTS: Seventy-eight studies (73 EVAR and 5 TEVAR) met inclusion criteria. TEVAR demonstrated significantly shorter FT than EVAR (15.25 vs. 28.50 min; P 85%). Only 11.5% of studies reported explicit as low as reasonably achievable compliance, and fusion imaging was used in 9%, more frequently in TEVAR. Publication bias was evident for all radiation metrics. CONCLUSION: Radiation exposure during EVAR and TEVAR varies substantially, reflecting anatomical complexity, imaging technology, and procedural practice. TEVAR required shorter FT but produced similar or higher KAP values, likely related to thoracic imaging geometry. Limited TEVAR data restrict the strength of comparative conclusions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece. Electronic address: fotis_efth@hotmail.gr.
- 1st Department of Vascular Surgery, Attikon University Hospital, National and Kapodistrian University of Athens, Athens, Greece.
- Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece.
- Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece; Department of Medical Physics, University Hospital of Patras, Patras, Greece.
- Department of Vascular Surgery, University Hospital of Patras, Patras, Greece.
Zitieren
APA
Efthymiou, F. O., Pitros, C. F., Antonopoulos, C. N., Metaxas, V. I., Dimitroukas, C. P., Panayiotakis, G. S., Kakisis, J. D., Kakkos, S. K., & Moulakakis, K. G. (2026). Fluoroscopy Time and Radiation Exposure in TEVAR Versus EVAR: A Systematic Review and Meta-Analysis. Annals of Vascular Surgery. https://doi.org/10.1016/j.avsg.2026.01.003
Vancouver
Efthymiou FO, Pitros CF, Antonopoulos CN, Metaxas VI, Dimitroukas CP, Panayiotakis GS, et al. Fluoroscopy Time and Radiation Exposure in TEVAR Versus EVAR: A Systematic Review and Meta-Analysis. Annals of Vascular Surgery. 2026. doi:10.1016/j.avsg.2026.01.003
BibTeX
@article{Efthymiou2026,
author = {Efthymiou, Fotios O and Pitros, Christos F and Antonopoulos, Constantine N and Metaxas, Vasileios I and Dimitroukas, Christos P and Panayiotakis, George S and Kakisis, John D and Kakkos, Stavros K and Moulakakis, Konstantinos G},
title = {Fluoroscopy Time and Radiation Exposure in TEVAR Versus EVAR: A Systematic Review and Meta-Analysis},
journal = {Annals of Vascular Surgery},
year = {2026},
doi = {10.1016/j.avsg.2026.01.003}
}
EUVIMED