E-STABILISE Technique: A Solution for Postdissection Thoracic Aortic Aneurysm Repair: The Association of Transcatheter Electosurgical Septotomy with the STABILISE Technique
Annals of Vascular Surgery · 2026-01 · 122 · 610-617
DOI: 10.1016/j.avsg.2025.08.044 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Vascular Surgery, 2026-01. Verfasst von Mauro Fresilli und 4 weiteren Autor:innen. Beteiligte Einrichtung: Vascular Surgery Unit, Department of Biomedicine and Prevention, Tor Vergata University, Rome, Italy. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracic, Aortic Dissection, Blood Vessel Prosthesis Implantation, Endovascular Procedures. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: Postdissection thoracic aortic aneurysm (PD-TAA) treatment represents one of the most challenging scenarios in vascular surgery, and has led to the development of various techniques. This is a retrospective single-center study aiming to show the early results of patients affected by PD-TAA treated by Transcatheter Electrosurgical Septotomy, followed by endovascular remodeling using the STent-Assisted Balloon-Induced intimaL dISruption and rElamination (STABILISE) in aortic dissection repair technique. METHODS: From January 2023 to December 2024, 10 patients were treated for PD-TAA using this technique. Aneurysmal degeneration involved both the aortic arch and thoracic aorta in 6 cases, while in the remaining 4 cases, only the descending thoracic aorta was involved. After endovascular repair of the aortic arch, when needed, and electrosurgical septotomy of the dissection lamella in the thoraco-abdominal tract, the procedure was completed by thoracic graft and dissection aortic stent placement, followed by aortic ballooning, performed in the same fashion as the STABILISE technique. RESULTS: Technical success and clinical success were achieved in 100% of cases. No intraoperative and 24-h death and aorta-related complications were recorded. No 30-day mortality was recorded. No aorta-related complication at 30 days was recorded in 9 cases. In one case, a type IB endoleak was recorded and was treated with a branched thoraco-abdominal endograft. CONCLUSION: These preliminary results suggest that the combination of the Transcatheter Electrosurgical Septotomy (TES) with the STABILISE technique is promising in a selected cohort of patients. Further studies are necessary to confirm these results.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Vascular Surgery Unit, Department of Biomedicine and Prevention, Tor Vergata University, Rome, Italy.
- Vascular Surgery Unit, Cardio-Toraco-Vascular Department, Policlinico Umberto I, Sapienza University of Rome, Rome, Italy. Electronic address: alessia.digirolamo@uniroma1.it.
Zitieren
APA
Fresilli, M., Oddi, F. M., Di Girolamo, A., Ippoliti, A., & Martelli, E. (2026). E-STABILISE Technique: A Solution for Postdissection Thoracic Aortic Aneurysm Repair: The Association of Transcatheter Electosurgical Septotomy with the STABILISE Technique. Annals of Vascular Surgery, 122, 610-617. https://doi.org/10.1016/j.avsg.2025.08.044
Vancouver
Fresilli M, Oddi FM, Di Girolamo A, Ippoliti A, Martelli E. E-STABILISE Technique: A Solution for Postdissection Thoracic Aortic Aneurysm Repair: The Association of Transcatheter Electosurgical Septotomy with the STABILISE Technique. Annals of Vascular Surgery. 2026;122:610-617. doi:10.1016/j.avsg.2025.08.044
BibTeX
@article{Fresilli2026,
author = {Fresilli, Mauro and Oddi, Fabio Massimo and Di Girolamo, Alessia and Ippoliti, Arnaldo and Martelli, Eugenio},
title = {E-STABILISE Technique: A Solution for Postdissection Thoracic Aortic Aneurysm Repair: The Association of Transcatheter Electosurgical Septotomy with the STABILISE Technique},
journal = {Annals of Vascular Surgery},
year = {2026},
volume = {122},
pages = {610--617},
doi = {10.1016/j.avsg.2025.08.044}
}