EUVIMEDEUVIMED entdecken
Vergleichsstudie

The Degree of Inferior Vena Cava Filter Tilt Associated with Challenging Retrieval

Valentyna Kostiuk, Scott Grubman, Anand Brahmandam, Eric Schneider, Britt H Tonnessen, Juan Carlos Perez Lozada, Raul J Guzman, Cassius Iyad Ochoa Chaar

Annals of Vascular Surgery · 2024-12 · 109 · 135-142

DOI: 10.1016/j.avsg.2024.06.020 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Annals of Vascular Surgery, 2024-12. Verfasst von Valentyna Kostiuk und 7 weiteren Autor:innen. Beteiligte Einrichtung: Yale University School of Medicine, New Haven, CT. Electronic address: valentyna.kostiuk@yale.edu. Hauptthemen laut MEDLINE: Vena Cava Filters, Device Removal, Vena Cava, Inferior, Prosthesis Implantation. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Inferior vena cava (IVC) filter tilt is associated with technical difficulties at the time of retrieval. However, the degree of tilt that predisposes patients to undergo complex or failed retrieval has not been defined. METHODS: The electronic charts of patients undergoing IVC filter removal between 2010 and 2019 at a single tertiary center were reviewed. Patient and procedural characteristics were recorded. Venograms of placement and retrieval procedures were reviewed, and IVC filter tilt was determined based on its deviation from the IVC axis. IVC diameter and the distance from the lowest renal vein were measured using corresponding filter's length for calibration. All measurements were performed by 3 reviewers and confirmed by 2 reviewers. Patients were divided into 2 groups: those who underwent successful removal procedures requiring standard retrieval methods ("simple retrieval group") and those who required advanced endovascular techniques or had failed completely IVC filter retrievals ("challenging retrieval group"). A regression analysis was performed to determine factors associated with challenging retrieval. RESULTS: There were 365 patients who underwent IVC filter retrieval (n = 294 (80.6%) and n = 71 (19.4%) in the simple and challenging groups, respectively) with no difference in age, sex, comorbidities, or indication between the 2 groups. Failed retrieval occurred in 21 patients (5.8%) and was more common among patients requiring advanced endovascular techniques compared to standard techniques (18.0% vs. 3.2%, P < 0.001). In the overall cohort, the mean filter tilt at the time of retrieval was 4.9° ± 4.4° [0c27°], and 145 patients (39.7%) had a filter tilt ≥5.0°. Compared to the simple retrieval group, patients in the challenging group had significantly longer dwell time, greater tilt of IVC filter during placement and retrieval, as well as higher tilt change between the 2 venograms. There was no correlation between the access site during placement and challenging retrieval. However, patients undergoing filter placement via right jugular vein had lower filter tilt as compared to femoral access. Patients with filter tilt ≥5.0° were more likely to have a challenging filter retrieval compared to patients with ˂5.0° tilt (29.7% vs. 12.7%, P < 0.001). Regression analysis showed that tilt ≥5.0° (odds ratio [OR] = 1.18 [1.11-1.25]), dwell time (OR = 1.04 [1.01-1.07]), and age (OR = 0.97 [0.95-0.99]) were independently associated with challenging retrieval. CONCLUSIONS: IVC filter tilt ≥5.0°, dwell time and age are associated with challenging retrieval. Right jugular vein access, multiple imaging projections, and careful filter manipulation during deployment should be considered to maintain tilt at ˂ 5.0° and decrease the likelihood of challenging retrieval.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vena Cava FiltersDevice RemovalVena Cava, InferiorProsthesis ImplantationHumansFemaleMaleRetrospective StudiesMiddle AgedRisk FactorsAgedAdultPhlebographyEndovascular ProceduresProsthesis DesignElectronic Health RecordsRisk AssessmentTreatment OutcomeTime Factors

Autor:innen und Institutionen

  • Yale University School of Medicine, New Haven, CT. Electronic address: valentyna.kostiuk@yale.edu.
  • Yale University School of Medicine, New Haven, CT.
  • Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Yale University School of Medicine, New Haven, CT.
  • Department of Surgery, Center for Health Services and Outcomes Research, Yale University School of Medicine, New Haven, CT.
  • Division of Interventional Radiology, Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, CT.

Zitieren

APA

Kostiuk, V., Grubman, S., Brahmandam, A., Schneider, E., Tonnessen, B. H., Perez Lozada, J. C., Guzman, R. J., & Ochoa Chaar, C. I. (2024). The Degree of Inferior Vena Cava Filter Tilt Associated with Challenging Retrieval. Annals of Vascular Surgery, 109, 135-142. https://doi.org/10.1016/j.avsg.2024.06.020

Vancouver

Kostiuk V, Grubman S, Brahmandam A, Schneider E, Tonnessen BH, Perez Lozada JC, et al. The Degree of Inferior Vena Cava Filter Tilt Associated with Challenging Retrieval. Annals of Vascular Surgery. 2024;109:135-142. doi:10.1016/j.avsg.2024.06.020

BibTeX
@article{Kostiuk2024,
  author = {Kostiuk, Valentyna and Grubman, Scott and Brahmandam, Anand and Schneider, Eric and Tonnessen, Britt H and Perez Lozada, Juan Carlos and Guzman, Raul J and Ochoa Chaar, Cassius Iyad},
  title = {The Degree of Inferior Vena Cava Filter Tilt Associated with Challenging Retrieval},
  journal = {Annals of Vascular Surgery},
  year = {2024},
  volume = {109},
  pages = {135--142},
  doi = {10.1016/j.avsg.2024.06.020}
}
Kostenlos starten →