EUVIMEDEUVIMED entdecken
Crossref

The Inferior Vena Cava Filter Placement Parameters May Predict Filter Retrieval Outcomes

Zhang-Wei Huang, Gui-Lin Yang, Qing Li, Bo Tang

Annals of Vascular Surgery · 2024

DOI: 10.1016/j.avsg.2024.06.018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Vascular Surgery, 2024. Verfasst von Zhang-Wei Huang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular, Abdominal & Hernia Surgery, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China. Hauptthemen laut MEDLINE: Vena Cava Filters, Device Removal, Vena Cava, Inferior, Prosthesis Implantation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: We aimed to investigate the potential correlation between the placement factors of various retrievable inferior vena cava filters and retrieval outcomes. Additionally, we aimed to identify the factors affecting the placement tilt of the filter. METHODS: This retrospective study was conducted at a tertiary care center to investigate patients who had previously undergone retrievable filter placement at our center and who subsequently had their filters removed between January 2020 and December 2021. Patient characteristics and filter-related factors were recorded. Complex filter retrieval was defined as cases that required a minimum of 8 minutes of fluoroscopy or that involved advanced techniques. Regression models were used to explore patient- and placement procedure-related factors that could influence retrieval outcomes and the placement tilt angle. RESULTS: The study included 163 patients, and all filters were successfully retrieved. Thirty-seven (22.7%) retrievals were classified as complex retrievals. The mean diameter of the inferior vena cava in the preplacement position for the entire cohort was 16 ± 1.8 mm. The median filter tilt angles at placement and retrieval were 5.0° (IQR, 1.8°-9°) and 4.6° (IQR, 2.1°-8.0°), respectively. The placement tilt angle was not significantly associated with complex retrieval (P = 0.59). The filter hook abutment to the vena cava wall (OR, 10.76, P = 0.003), dwell time (OR, 1.02, P = 0.029), and diameter of the vena cava (OR, 10.21, P < 0.001) were associated with complex retrieval. The diameter (P = 0.049), age (P = 0.049), and filter brand (P = 0.001) were found to be significantly associated with placement tilt. CONCLUSIONS: The inferior vena cava diameter at the time of placement predicts difficulty in filter retrieval. In addition, the filter hook abutting the inferior vena cava wall and long indwelling time may complicate retrieval. The vena cava diameter is also closely related to the degree of filter tilt.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vena Cava FiltersDevice RemovalVena Cava, InferiorProsthesis ImplantationHumansRetrospective StudiesMaleFemaleMiddle AgedTreatment OutcomeAgedRisk FactorsAdultTime FactorsProsthesis DesignRisk Assessment

Autor:innen und Institutionen

  • Department of Vascular, Abdominal & Hernia Surgery, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Department of Hematology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Department of Vascular, Abdominal & Hernia Surgery, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China. Electronic address: 300374@hospital.cqmu.edu.cn.

Zitieren

APA

Huang, Z. W., Yang, G. L., Li, Q., & Tang, B. (2024). The Inferior Vena Cava Filter Placement Parameters May Predict Filter Retrieval Outcomes. Annals of Vascular Surgery. https://doi.org/10.1016/j.avsg.2024.06.018

Vancouver

Huang ZW, Yang GL, Li Q, Tang B. The Inferior Vena Cava Filter Placement Parameters May Predict Filter Retrieval Outcomes. Annals of Vascular Surgery. 2024. doi:10.1016/j.avsg.2024.06.018

BibTeX
@article{Huang2024,
  author = {Huang, Zhang-Wei and Yang, Gui-Lin and Li, Qing and Tang, Bo},
  title = {The Inferior Vena Cava Filter Placement Parameters May Predict Filter Retrieval Outcomes},
  journal = {Annals of Vascular Surgery},
  year = {2024},
  doi = {10.1016/j.avsg.2024.06.018}
}
Kostenlos starten →