Characteristics of Option and Denali Inferior Vena Cava Filters
Annals of Vascular Surgery · 2024-02 · 99 · 349-355
DOI: 10.1016/j.avsg.2023.08.042 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Vascular Surgery, 2024-02. Verfasst von Lihao Qin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional and Vascular Surgery, The Affiliated Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China. Hauptthemen laut MEDLINE: Vena Cava Filters. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 15 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: To assess the characteristics of Option and Denali filters and to identify associations between these characteristics in each filter type. METHODS: Consecutive patients who underwent Option or Denali filter placement between August 2019 and August 2022 were included in this retrospective study. RESULTS: A total of 119 patients (Option, n = 60; Denali, n = 59) were included. The retrieval rates were 45.0% for Option filters and 40.7% for Denali filters. The incidence of tilt at placement was higher for Option filters (76.7%) than for Denali filters (11.9%; P < 0.001). The tilt angle of Option filters at placement was correlated with the common iliac vein-inferior vena cava (CIV-IVC) angle. The incidence of tilt angle change after placement was higher for Option filters (74.1%) than for Denali filters (8.3%; P = 0.001). The IVC contraction rate after retrieval of Option is less than Denali (22.2% vs. 87.5%, P < 0.001). The median fluoroscopy time during Option filter retrieval was longer than during Denali filter retrieval. The fluoroscopic time was related to tilt angle during retrieval of Option filters. CONCLUSIONS: Option filters are more likely than Denali filters to tilt at placement, and the tilt angle of Option filters is more prone to change after placement. The tilt angle at placement in Option filters is related to the CIV-IVC angle. Option filters require a longer fluoroscopic time during retrieval than Denali filters, and this increased fluoroscopic time is related to the tilt angle. Denali is more likely to cause IVC constriction after placement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Interventional and Vascular Surgery, The Affiliated Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China.
- Department of Interventional Radiology, Huaian Hospital of Huaian City (Huaian Cancer Hospital), Huaian, China. Electronic address: vh6376@163.com.
- Department of Interventional and Vascular Surgery, The Affiliated Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China. Electronic address: 352010950@qq.com.
- Department of Interventional and Vascular Surgery, The Affiliated Changzhou Second People's Hospital, Nanjing Medical University, Changzhou, China. Electronic address: 1181487460@qq.com.
Zitieren
APA
Qin, L., Gu, X., Wang, K., Jia, Z., Xue, T., Li, S., & Wang, K. (2024). Characteristics of Option and Denali Inferior Vena Cava Filters. Annals of Vascular Surgery, 99, 349-355. https://doi.org/10.1016/j.avsg.2023.08.042
Vancouver
Qin L, Gu X, Wang K, Jia Z, Xue T, Li S, et al. Characteristics of Option and Denali Inferior Vena Cava Filters. Annals of Vascular Surgery. 2024;99:349-355. doi:10.1016/j.avsg.2023.08.042
BibTeX
@article{Qin2024,
author = {Qin, Lihao and Gu, Xiaocheng and Wang, Kai and Jia, Zhongzhi and Xue, Tongqing and Li, Shaoqin and Wang, Ke},
title = {Characteristics of Option and Denali Inferior Vena Cava Filters},
journal = {Annals of Vascular Surgery},
year = {2024},
volume = {99},
pages = {349--355},
doi = {10.1016/j.avsg.2023.08.042}
}
EUVIMED