EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Is Fretting Corrosion at the Modular Junction of Revision Total Knee Arthroplasty Actually a Problem?

Deborah J Hall, John Wong, Jennifer L Wright, Julia P Hochstatter, Robert A Burnett, Amy Miller, Brett R Levine, Robin Pourzal, E Bailey Terhune

The Journal of Arthroplasty · 2026

DOI: 10.1016/j.arth.2026.05.069 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2026. Verfasst von Deborah J Hall und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Prosthesis Failure, Knee Prosthesis. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIAMS NIH HHS, National Institute of Arthritis and Musculoskeletal and Skin Diseases.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Corrosion at modular junctions in total knee arthroplasty (TKA) implants is recognized, but its clinical relevance remains unclear. This study evaluated corrosion at modular stem-bore junctions and examined whether severity correlated with radiographic evidence of adverse local tissue reactions or osteolysis. METHODS: We evaluated 196 retrieved modular stem and bore components from 98 revision TKA patients, including taper (n = 73) and threaded (n = 25) designs. The median time in situ was 24 months for taper and 15 months for threaded junctions (P = 0.052). Periprosthetic joint infection and aseptic loosening were the most common indications for component explantation. Fretting corrosion at the modular junction was graded using a modified Goldberg Score (mGS) and quantified using an optical coordinate measuring machine. Radiographs were evaluated. Statistical analyses included Mann-Whitney U-, Chi-Square, and Spearman's correlation tests. RESULTS: Taper junctions demonstrated greater corrosion than threaded designs (P < 0.001). The median mGS for modular tapers was 4 for femoral components, 3 for femoral stems, and two for both tibial components and stems. Threaded junctions showed minimal damage across all interfaces with a median score of 1. Damage patterns included fretting wear, corrosion features, and dark deposits. Among cobalt-chromium (CoCr) femoral bore tapers with mGS of 4, median material loss was 0.56 mm3. Titanium alloy femoral and tibial stem tapers showed a median loss of 0.071 mm3, and 0.067 mm3, respectively. Corrosion severity did not correlate with localized radiographic findings or indication for revision. CONCLUSIONS: In this study of modular TKA components, taper junctions exhibited significantly more corrosion than threaded junctions. However, corrosion severity was not associated with radiographic findings or etiology of failure. Corrosion products differed from those typically observed in THA, suggesting a distinct mechanism. Further research is required to clarify potential clinical implications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeProsthesis FailureKnee ProsthesisHumansReoperationCorrosionProsthesis DesignAgedFemaleMaleMiddle AgedAged, 80 and overRadiography

Stichwörter der Autor:innen

fretting corrosionmodular junctionrevision knee arthroplastytaper damagetotal knee arthroplasty

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois.
  • Department of Orthopedic Surgery, MedStar Georgetown University Hospital, Washington, District of Columbia.

Förderung

  • NIAMS NIH HHS
  • National Institute of Arthritis and Musculoskeletal and Skin Diseases

Zitieren

APA

Hall, D. J., Wong, J., Wright, J. L., Hochstatter, J. P., Burnett, R. A., Miller, A., Levine, B. R., Pourzal, R., & Terhune, E. B. (2026). Is Fretting Corrosion at the Modular Junction of Revision Total Knee Arthroplasty Actually a Problem?. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2026.05.069

Vancouver

Hall DJ, Wong J, Wright JL, Hochstatter JP, Burnett RA, Miller A, et al. Is Fretting Corrosion at the Modular Junction of Revision Total Knee Arthroplasty Actually a Problem?. The Journal of Arthroplasty. 2026. doi:10.1016/j.arth.2026.05.069

BibTeX
@article{Hall2026,
  author = {Hall, Deborah J and Wong, John and Wright, Jennifer L and Hochstatter, Julia P and Burnett, Robert A and Miller, Amy and Levine, Brett R and Pourzal, Robin and Terhune, E Bailey},
  title = {Is Fretting Corrosion at the Modular Junction of Revision Total Knee Arthroplasty Actually a Problem?},
  journal = {The Journal of Arthroplasty},
  year = {2026},
  doi = {10.1016/j.arth.2026.05.069}
}
Kostenlos starten →