EUVIMEDEUVIMED entdecken
Crossref

Cobalt Chrome Heads Underperform Ceramic and Ceramicized Metal Heads in the Younger Population: An American Joint Replacement Registry Report

Akshay R Reddy, Emilie N Miley, Mahveen Jahan, Hari K Parvataneni, Hernan A Prieto, Chancellor F Gray

The Journal of Arthroplasty · 2025

DOI: 10.1016/j.arth.2025.09.003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von Akshay R Reddy und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Medicine, University of Florida, Gainesville, Florida. Hauptthemen laut MEDLINE: Hip Prosthesis, Arthroplasty, Replacement, Hip, Prosthesis Design, Prosthesis Failure. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The impact of fourth-generation ceramic, ceramicized metal, and antioxidant polyethylene has not been well characterized in younger patients undergoing total hip arthroplasty (THA). This study aimed to compare the revision rates of modern bearing couples in this population. METHODS: American Joint Replacement Registry data was analyzed between January 2012 and June 2022 for patients aged 18 to 54 years who underwent a primary THA, had at least 1-year follow-up, and received one of six bearing types (ceramic on ceramic [CoC], ceramic on cross-linked polyethylene [CoP], ceramic on antioxidant polyethylene [CoAOP], ceramicized metal on cross-linked polyethylene [CMoP], cobalt chromium on CoP ["metal on polyethylene," MoP], and metal on antioxidant polyethylene). Outcomes were assessed through analysis of variance, chi-square, and Fisher exact tests. Cox proportional hazard models were conducted and reported as hazard ratios (HRs) and confidence intervals (CIs). RESULTS: A total of 101,313 primary THA cases were identified; most patients received a CoP bearing (64.2%), and survivorship exceeded 96%. Also, CMoP had the lowest rate and a lower likelihood of all-cause revision compared to MoP (1.95%, n = 197; HR = 0.72; CIs: 0.59 to 0.87; P < 0.001). In addition to CMoP, CoP (HR = 0.73; CIs: 0.64 to 0.84; P < 0.001) and CoAOP (HR = 0.77; CIs: 0.64 to 0.94; P = 0.003) outperformed MoP. The lowest rate of revision for aseptic loosening was seen with CoC (P < 0.001), with CoAOP (HR = 0.41; CIs: 0.27 to 0.64; P < 0.001), CMoP (HR = 0.42; CIs: 0.56 to 0.70; P < 0.001), and CoP (HR = 0.55; CIs: 0.41 to 0.74; P < 0.001) also outperforming MoP. CONCLUSIONS: All-cause revision rates in this younger population are low with modern bearings. Head composition remains an important driver of survivorship. Ceramic or ceramicized metal on a polyethylene bearing should be considered the gold standard in this patient population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hip ProsthesisArthroplasty, Replacement, HipProsthesis DesignProsthesis FailureChromium AlloysHumansAdultMaleMiddle AgedFemaleRegistriesReoperationYoung AdultCeramicsAdolescentUnited States

Stichwörter der Autor:innen

AJRRBearing couplesimplant wearrevision total hip arthroplastytribology

Substanzen

Chromium Alloys

Autor:innen und Institutionen

  • College of Medicine, University of Florida, Gainesville, Florida.
  • Department of Health, Nutrition, and Food Sciences, Florida State University, Institute of Sports Sciences and Medicine, Tallahassee, Florida; Tallahassee Orthopedic Clinic, Tallahassee, Florida.
  • American Academy of Orthopaedic Surgeons (AAOS), Rosemont, Illinois.
  • Florida Orthopaedic Institute, Gainesville, Florida.
  • Department of Orthopaedic Surgery and Sports Medicine, College of Medicine, University of Florida, Gainesville, Florida.

Zitieren

APA

Reddy, A. R., Miley, E. N., Jahan, M., Parvataneni, H. K., Prieto, H. A., & Gray, C. F. (2025). Cobalt Chrome Heads Underperform Ceramic and Ceramicized Metal Heads in the Younger Population: An American Joint Replacement Registry Report. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2025.09.003

Vancouver

Reddy AR, Miley EN, Jahan M, Parvataneni HK, Prieto HA, Gray CF. Cobalt Chrome Heads Underperform Ceramic and Ceramicized Metal Heads in the Younger Population: An American Joint Replacement Registry Report. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2025.09.003

BibTeX
@article{Reddy2025,
  author = {Reddy, Akshay R and Miley, Emilie N and Jahan, Mahveen and Parvataneni, Hari K and Prieto, Hernan A and Gray, Chancellor F},
  title = {Cobalt Chrome Heads Underperform Ceramic and Ceramicized Metal Heads in the Younger Population: An American Joint Replacement Registry Report},
  journal = {The Journal of Arthroplasty},
  year = {2025},
  doi = {10.1016/j.arth.2025.09.003}
}
Kostenlos starten →