EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The association of bearing surface materials with the risk of revision following primary total hip replacement: A cohort analysis of 1,026,481 hip replacements from the National Joint Registry

Michael R Whitehouse, Rita Patel iD, Jonathan M R French iD, Andrew D Beswick iD, Patricia Navvuga iD, Elsa M R Marques, Ashley W Blom, Erik Lenguerrand iD

PLOS Medicine · 2024

DOI: 10.1371/journal.pmed.1004478 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS Medicine, 2024. Verfasst von Michael R Whitehouse und 7 weiteren Autor:innen. Beteiligte Einrichtung: University of Bristol Medical School, Translational Health Sciences, Musculoskeletal Research Unit, Bristol, United Kingdom. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Reoperation, Registries, Hip Prosthesis. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CeramTec GmbH, NIHR Bristol Biomedical Research Centre, NIHR, Comprehensive Clinical Research Network.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The risk of re-operation, otherwise known as revision, following primary hip replacement depends in part on the prosthesis implant materials used. Current performance evidences are based on a broad categorisation grouping together different materials with potentially varying revision risks. We investigated the revision rate of primary total hip replacement (THR) reported in the National Joint Registry by specific types of bearing surfaces used. Methods and findings We analysed THR procedures across all orthopaedic units in England and Wales. All patients who received a primary THR between 2003 and 2019 in the public and private sectors were included. We investigated the all-cause and indication-specific risks of revision using flexible parametric survival analyses to estimate adjusted hazard ratios (HRs). We identified primary THRs with heads and monobloc cups or modular acetabular component THRs with head and shell/liner combinations. A total of 1,026,481 primary THRs were analysed (Monobloc: n = 378,979 and Modular: n = 647,502) with 20,869 (2%) of these primary THRs subsequently undergoing a revision episode (Monobloc: n = 7,381 and Modular: n = 13,488). For monobloc implants, compared to implants with a cobalt chrome head and highly crosslinked polyethylene (HCLPE) cup, the all-cause risk of revision for monobloc acetabular implant was higher for patients with cobalt chrome (hazard rate at 10 years after surgery: 1.28 95% confidence intervals [1.10, 1.48]) or stainless steel head (1.18 [1.02, 1.36]) and non-HCLPE cup. The risk of revision was lower for patients with a delta ceramic head and HCLPE cup implant, at any postoperative period (1.18 [1.02, 1.36]). For modular implants, compared to patients with a cobalt chrome head and HCLPE liner primary THR, the all-cause risk of revision for modular acetabular implant varied non-constantly. THRs with a delta ceramic (0.79 [0.73, 0.85]) or oxidised zirconium (0.65 [0.55, 0.77]) head and HCLPE liner had a lower risk of revision throughout the entire postoperative period. Similar results were found when investigating the indication-specific risks of revision for both the monobloc and modular acetabular implants. While this large, nonselective analysis is the first to adjust for numerous characteristics collected in the registry, residual confounding cannot be rule out.

Conclusions

Prosthesis revision is influenced by the prosthesis materials used in the primary procedure with the lowest risk for implants with delta ceramic or oxidised zirconium head and an HCLPE liner/cup. Further work is required to determine the association of implant bearing materials with the risk of rehospitalisation, re-operation other than revision, mortality, and the cost-effectiveness of these materials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipReoperationRegistriesHip ProsthesisProsthesis DesignProsthesis FailureHumansFemaleMaleAgedMiddle AgedRisk FactorsWalesCohort StudiesEnglandAged, 80 and overAdultPolyethylene

Substanzen

Polyethylene

Autor:innen und Institutionen

  • University of Bristol Medical School, Translational Health Sciences, Musculoskeletal Research Unit, Bristol, United Kingdom.
  • National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol and Weston NHS Foundation Trust and University of Bristol, Bristol, United Kingdom.
  • Faculty of Health, University of Sheffield, Sheffield, United Kingdom.

ORCID-Profile: Rita Patel, Jonathan M R French, Andrew D Beswick, Patricia Navvuga, Erik Lenguerrand

Förderung

  • CeramTec GmbH
  • NIHR Bristol Biomedical Research Centre
  • NIHR, Comprehensive Clinical Research Network

Zitieren

APA

Whitehouse, M. R., Patel, R., French, J. M. R., Beswick, A. D., Navvuga, P., Marques, E. M. R., Blom, A. W., & Lenguerrand, E. (2024). The association of bearing surface materials with the risk of revision following primary total hip replacement: A cohort analysis of 1,026,481 hip replacements from the National Joint Registry. PLOS Medicine. https://doi.org/10.1371/journal.pmed.1004478

Vancouver

Whitehouse MR, Patel R, French JMR, Beswick AD, Navvuga P, Marques EMR, et al. The association of bearing surface materials with the risk of revision following primary total hip replacement: A cohort analysis of 1,026,481 hip replacements from the National Joint Registry. PLOS Medicine. 2024. doi:10.1371/journal.pmed.1004478

BibTeX
@article{Whitehouse2024,
  author = {Whitehouse, Michael R and Patel, Rita and French, Jonathan M R and Beswick, Andrew D and Navvuga, Patricia and Marques, Elsa M R and Blom, Ashley W and Lenguerrand, Erik},
  title = {The association of bearing surface materials with the risk of revision following primary total hip replacement: A cohort analysis of 1,026,481 hip replacements from the National Joint Registry},
  journal = {PLOS Medicine},
  year = {2024},
  doi = {10.1371/journal.pmed.1004478}
}
Kostenlos starten →