EUVIMEDEUVIMED entdecken
Crossref

Broach Only Total Hip Arthroplasty Using a Short, Uncemented, and Collarless, Fit-and-Fill Stem: Average 5-Year Follow-Up

John B Meding, Lindsey K Meding, Evan R Deckard, Leonard T Buller, R Michael Meneghini

The Journal of Arthroplasty · 2025

DOI: 10.1016/j.arth.2025.03.032 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von John B Meding und 4 weiteren Autor:innen. Beteiligte Einrichtung: Indiana Joint Replacement Institute, Noblesville, Indiana. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Prosthesis Design. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Short femoral stem use in total hip arthroplasty can preserve bone stock and may diminish thigh pain. Tapered-wedge short stems are appealing, because reaming is not typically required as it is with classic "fit-and-fill" designed stems. This study aimed to evaluate the minimum 2-year clinical, radiographic, and clinical results of a short, uncemented, and collarless, fit-and-fill stem implanted using a broach-only technique. METHODS: The clinical and radiographic results of a consecutive series of 505 cementless THAs were reviewed from 2 to 9 years postoperatively. The average age was 62 years (range, 32 to 91), and 54% of the patients were men. Dorr's class was 31% A, 64% B, and 5% C. All patients were followed for a minimum of 2 years. The average follow-up was 5.6 years (range, two to nine). RESULTS: At the final follow-up, the average Harris hip and pain scores were 90 and 42, respectively. There were 82% of hips rated as pain-free. A single patient reported activity-related thigh pain. There were no cases of femoral aseptic loosening. At operation, 14% of stems were placed in more than five degrees of varus. An intraoperative femur fracture occurred in 13 hips (2.5%). There were two stems revised (one infection and one late femur fracture). CONCLUSIONS: The theoretical advantages of using this collarless fit-and-fill stem may be offset by the tendency for varus placement and proximal femur fracture when using a broach-only technique. Nevertheless, the varus stems in this series remain well-ingrown and radiographically stable at an average 5-year follow-up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisProsthesis DesignHumansMaleMiddle AgedFemaleAgedFollow-Up StudiesAged, 80 and overAdultTreatment OutcomeRetrospective StudiesHip JointRadiography

Stichwörter der Autor:innen

collarlessfemoral componentfollow-upshort-stemmeduncemented

Autor:innen und Institutionen

  • Indiana Joint Replacement Institute, Noblesville, Indiana.
  • The Department of Orthopaedic Surgery, Indiana University School of Medicine, The IU Hip and Knee Center, Fishers, Indiana.
  • Indiana Joint Replacement Institute, Noblesville, Indiana; The Department of Orthopaedic Surgery, Indiana University School of Medicine, The IU Hip and Knee Center, Fishers, Indiana.

Zitieren

APA

Meding, J. B., Meding, L. K., Deckard, E. R., Buller, L. T., & Meneghini, R. M. (2025). Broach Only Total Hip Arthroplasty Using a Short, Uncemented, and Collarless, Fit-and-Fill Stem: Average 5-Year Follow-Up. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2025.03.032

Vancouver

Meding JB, Meding LK, Deckard ER, Buller LT, Meneghini RM. Broach Only Total Hip Arthroplasty Using a Short, Uncemented, and Collarless, Fit-and-Fill Stem: Average 5-Year Follow-Up. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2025.03.032

BibTeX
@article{Meding2025,
  author = {Meding, John B and Meding, Lindsey K and Deckard, Evan R and Buller, Leonard T and Meneghini, R Michael},
  title = {Broach Only Total Hip Arthroplasty Using a Short, Uncemented, and Collarless, Fit-and-Fill Stem: Average 5-Year Follow-Up},
  journal = {The Journal of Arthroplasty},
  year = {2025},
  doi = {10.1016/j.arth.2025.03.032}
}
Kostenlos starten →