Using Porous Tantalum Uncemented Components to Manage Acetabular Defects and to Restore the Hip Center of Rotation in Revision Total Hip Arthroplasty: A Minimum Ten-Year Clinical and Radiological Study
The Journal of Arthroplasty · 2025
DOI: 10.1016/j.arth.2024.10.110 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von Alessandra Cipolla und 4 weiteren Autor:innen. Beteiligte Einrichtung: University of Turin, CTO Hospital (C.T.O. Centro Traumatologico Ortopedico), Torino, Italy; Aix-Marseille University, AP-HM, CNRS, ISM, Sainte-Margue…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Tantalum, Hip Prosthesis, Acetabulum. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Managing acetabular defects and restoring the hip center of rotation (COR) in revision hip arthroplasty is considered a complex and challenging surgery. Among many existing options, porous tantalum components have shown favorable short-term (less than ten years) follow-up results. The present study aimed to describe clinical and radiographic outcomes in longer-term follow-up. METHODS: Between 2006 and 2013, 98 patients who underwent this surgical technique in our institute were clinically and radiographically reviewed. Rerevisions for aseptic loosening of the acetabular component were examined to consider the survivorship of the implant as the primary endpoint. The clinical outcome was measured using the Harris Hip Score. Radiological signs of osseointegration, radiolucency lines, acetabular stability, and position of the hip COR were evaluated at the immediate postoperative and last follow-up radiographs. RESULTS: The cup survivorship was 96% at a mean follow-up of 14 years (range, 10 to 17). Global survivorship was 83.6% if any reason for rerevisions was considered an endpoint. The most frequent complications were dislocation (13.7%) and infections (12%). Overall, 13 patients died, and 17 patients were lost to follow-up. There were 73 patients available for clinical and radiographic evaluation. The mean Harris Hip Score was 81 (range, 39 to 100). More than 80% of hips showed radiological evidence of osseointegration, and no change was found in COR position at last follow-up radiographs. CONCLUSIONS: The use of porous tantalum uncemented components to manage revision hip arthroplasty can be considered a favorable solution for managing acetabular defects and restoring the hip COR with satisfactory clinical and radiological results in a long-term follow-up.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- University of Turin, CTO Hospital (C.T.O. Centro Traumatologico Ortopedico), Torino, Italy; Aix-Marseille University, AP-HM, CNRS, ISM, Sainte-Marguerite Hospital, Institute for Locomotion, Department of Orthopedics and…
- Aix-Marseille University, AP-HM, CNRS, ISM, Sainte-Marguerite Hospital, Institute for Locomotion, Department of Orthopedics and Traumatology, Marseille, France; MSk Lab - Imperial College London, Department of Surgery &…
- Aix-Marseille University, AP-HM, CNRS, ISM, Sainte-Marguerite Hospital, Institute for Locomotion, Department of Orthopedics and Traumatology, Marseille, France; Service de Chirurgie Orthopédique, Hôpital Nord, Pôle Loco…
- Aix-Marseille University, AP-HM, CNRS, ISM, Sainte-Marguerite Hospital, Institute for Locomotion, Department of Orthopedics and Traumatology, Marseille, France.
Zitieren
APA
Cipolla, A., Vella-Baldacchino, M., Le Baron, M., Argenson, J. N., & Flecher, X. (2025). Using Porous Tantalum Uncemented Components to Manage Acetabular Defects and to Restore the Hip Center of Rotation in Revision Total Hip Arthroplasty: A Minimum Ten-Year Clinical and Radiological Study. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2024.10.110
Vancouver
Cipolla A, Vella-Baldacchino M, Le Baron M, Argenson JN, Flecher X. Using Porous Tantalum Uncemented Components to Manage Acetabular Defects and to Restore the Hip Center of Rotation in Revision Total Hip Arthroplasty: A Minimum Ten-Year Clinical and Radiological Study. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2024.10.110
BibTeX
@article{Cipolla2025,
author = {Cipolla, Alessandra and Vella-Baldacchino, Martinique and Le Baron, Marie and Argenson, Jean-Noel and Flecher, Xavier},
title = {Using Porous Tantalum Uncemented Components to Manage Acetabular Defects and to Restore the Hip Center of Rotation in Revision Total Hip Arthroplasty: A Minimum Ten-Year Clinical and Radiological Study},
journal = {The Journal of Arthroplasty},
year = {2025},
doi = {10.1016/j.arth.2024.10.110}
}