Reconstruction of severe acetabular defects (Paprosky type III A) in total hip arthroplasty using modular tantalum augments in combination with a cemented cup
International Orthopaedics · 2024
DOI: 10.1007/s00264-024-06334-x ↗Kurz gefasst
Fachartikel in der Zeitschrift International Orthopaedics, 2024. Verfasst von David Spranz und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, University Hospital Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Tantalum, Acetabulum, Hip Prosthesis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutschen Arthrose-Hilfe, Universitätsklinikum Heidelberg.
Abstract (Originalsprache)
Purpose
Acetabular defect reconstruction can be a complex and challenging surgical procedure, with stable long-term fixation of the implants remaining the ultimate goal. The purpose of this study was (1) to evaluate the radiological and clinical outcome of complex acetabular reconstruction surgery with the use of modular tantalum TM augments in combination with cemented revision cups; (2) to investigate blood tantalum concentrations in these patients; and (3) to report complications and mechanisms of failure related to this procedure at mid-term follow-up (mean 4.5 years).
Methods
We retrospectively reviewed 29 patients (29 hips) with severe acetabular bone loss (Paprosky type III A) reconstructed using a modular tantalum TM augment in combination with a cemented cup. We evaluated the implant survival and the radiological and clinical outcomes after a mean follow-up of 4.5 years (SD 2.2; range 8.4 – 2.1 years) using patient reported outcome scores (PROMs). Blood samples were analysed regarding tantalum concentration and compared with a control group.
Results
The cumulative survival rate at 4.5 years with the endpoint “revision of the acetabular component for any reason” was 96.2% (95% Confidence Interval 75.7–99.5). The PROMs improved significantly up to the latest follow-up, and radiographic data showed only one patient with signs of initial implant migration with a broken screw and a change of the position of the augment and the cup. Mean blood tantalum concentrations were significantly higher in the study group (0.16 µg/L) compared to the control group (0.002 µg/L) ( P < 0.001).
Conclusions
This study has demonstrated good mid-term (mean 4.5 years) clinical and radiological outcomes of modular tantalum TM augments in combination with a cemented cup for the reconstruction of major acetabular defects. Mean blood tantalum concentrations were increased in patients with stable tantalum implants compared to healthy controls.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopaedics, University Hospital Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany.
- Department of Orthopaedics, University Hospital Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany. Tobias.Reiner@med.uni-heidelberg.de.
Förderung
- Deutschen Arthrose-Hilfe
- Universitätsklinikum Heidelberg
Zitieren
APA
Spranz, D., Müller, L. M., Trefzer, R., Hetto, P., Nees, T., Renkawitz, T., Walker, T., & Reiner, T. (2024). Reconstruction of severe acetabular defects (Paprosky type III A) in total hip arthroplasty using modular tantalum augments in combination with a cemented cup. International Orthopaedics. https://doi.org/10.1007/s00264-024-06334-x
Vancouver
Spranz D, Müller LM, Trefzer R, Hetto P, Nees T, Renkawitz T, et al. Reconstruction of severe acetabular defects (Paprosky type III A) in total hip arthroplasty using modular tantalum augments in combination with a cemented cup. International Orthopaedics. 2024. doi:10.1007/s00264-024-06334-x
BibTeX
@article{Spranz2024,
author = {Spranz, David and Müller, Lisa-Marie and Trefzer, Raphael and Hetto, Pit and Nees, Timo and Renkawitz, Tobias and Walker, Tilman and Reiner, Tobias},
title = {Reconstruction of severe acetabular defects (Paprosky type III A) in total hip arthroplasty using modular tantalum augments in combination with a cemented cup},
journal = {International Orthopaedics},
year = {2024},
doi = {10.1007/s00264-024-06334-x}
}
EUVIMED