Decreased “Polar Axis Angle” is Associated With Instability After Total Hip Arthroplasty: A New Method to Assess Functional Component Position on Lateral-Seated Radiographs
The Journal of Arthroplasty · 2024-12 · 39 (12) · 3021-3027
DOI: 10.1016/j.arth.2024.06.039 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024-12. Verfasst von Alex J Anatone und 5 weiteren Autor:innen. Beteiligte Einrichtung: Adult Reconstruction and Joint Replacement Service, Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Radiography, Joint Instability. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Research on hip instability has focused on establishing "safe" ranges of combined component position in supine posture or functional placement of the acetabular component based on the hip-spine relationship. A new angle, the polar axis angle (PAA), of the total hip arthroplasty (THA) components describes the concentricity of both components and can be evaluated in functional positions that confer a greater risk of instability (ie, sitting). The goal of this study was to compare the PAA in functional positions between patients who experienced a postoperative dislocation and a matched control group who did not have a dislocation. METHODS: An institutional database was searched for patients experiencing a dislocation after primary THA. Patients who had postoperative full-length standing and lateral-seatedradiographs were included in the dislocator group. A control group of nondislocator patients was matched 2:1 by age, body mass index, sex, and hip-spine classification. Radiographic measurements of the neck angle, acetabular ante-inclination, and PAA were performed by 2 separate blinded, trained reviewers. RESULTS: The lateral-seated neck angle and lateral-seated PAA measurements were significantly lower in the dislocator groups (n = 37) than the control group (n = 74) (23 versus 33 degrees, P < .001; 74 versus 83 degrees, P = .012, respectively). Significant differences were also observed in changes in the polar axes and neck angles between standing and seated positions (P < .001 and P < .001, respectively). When comparing patients who have mobile spines versus stiff spines within the dislocator group, there were no differences in the acetabular, neck, or PAAs. The effect of neck angle on the PAA showed a linear trend across cohorts. CONCLUSIONS: Patients who experience postoperative instability have a significantly lower PAA on lateral-seated radiographs when matched for age, sex, body mass index, and hip-spine classification. In addition, the lower seated PAA is driven more strongly by decreased functional femoral anteversion, which emphasizes the role of functional femoral version on stability in THA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Adult Reconstruction and Joint Replacement Service, Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York.
- Adult Reconstruction and Joint Replacement Service, Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York; The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of…
Zitieren
APA
Anatone, A. J., Hughes, A. J., Schiller, N. C., Vigdorchik, J. M., Sculco, T. P., & Sculco, P. K. (2024). Decreased “Polar Axis Angle” is Associated With Instability After Total Hip Arthroplasty: A New Method to Assess Functional Component Position on Lateral-Seated Radiographs. The Journal of Arthroplasty, 39(12), 3021-3027. https://doi.org/10.1016/j.arth.2024.06.039
Vancouver
Anatone AJ, Hughes AJ, Schiller NC, Vigdorchik JM, Sculco TP, Sculco PK. Decreased “Polar Axis Angle” is Associated With Instability After Total Hip Arthroplasty: A New Method to Assess Functional Component Position on Lateral-Seated Radiographs. The Journal of Arthroplasty. 2024;39(12):3021-3027. doi:10.1016/j.arth.2024.06.039
BibTeX
@article{Anatone2024,
author = {Anatone, Alex J and Hughes, Andrew J and Schiller, Nicholas C and Vigdorchik, Jonathan M and Sculco, Thomas P and Sculco, Peter K},
title = {Decreased “Polar Axis Angle” is Associated With Instability After Total Hip Arthroplasty: A New Method to Assess Functional Component Position on Lateral-Seated Radiographs},
journal = {The Journal of Arthroplasty},
year = {2024},
volume = {39},
number = {12},
pages = {3021--3027},
doi = {10.1016/j.arth.2024.06.039}
}
EUVIMED