EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Tibial Slope Is Not Associated With Implant Migration Following Cemented Total Knee Arthroplasty With a Single Implant Design

Glen Richardson, Matthew J Kivell, Michael J Dunbar, Elise K Laende

The Journal of Arthroplasty · 2024

DOI: 10.1016/j.arth.2024.04.021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024. Verfasst von Glen Richardson und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Sc…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Tibia, Knee Prosthesis, Prosthesis Failure. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Atlantic Canada Opportunities Agency, Canadian Orthopaedic Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The influence of tibial slope on tibial component migration following total knee arthroplasty has not been widely studied, although excessive posterior slope has been implicated in some failures. As implant micromotion measured with radiostereometric analysis can indicate successful fixation, the purpose of this study was to determine the associations between tibial slope, tibial component migration, and inducible displacement. METHODS: Radiostereometric analyses at 6 visits over 2 years quantified implant migration for 200 cemented total knee arthroplasties. Longitudinal data analysis examined the influence of postoperative tibial slope on implant migration (overall maximum total point motion (MTPM) migration and anterior-posterior tilt migration), accounting for age, sex, and body mass index. The correlations of tibial slope with 1-year migration, continuous migration, and inducible displacements were also examined. Additionally, the amount of change in slope was compared to migration. RESULTS: The mean posterior tibial slope was 8.0° (standard deviation [SD] 3.8°) preoperatively and 3.8° (SD 3.1°) postoperatively, with a mean reduction in slope of 4.2° (SD 4.7°). Postoperative tibial slope (range 14.0° posterior slope to 3.4° anterior slope) was not associated with longitudinal overall migration (P = .671) or anterior-posterior tilt migration (P = .704). There was no association between postoperative tibial slope and migration at 1 year postoperatively (P = .441 for MTPM migration, P = .570 for tilt migration), change in migration from 1 to 2 years (P = .951), or inducible displacement (P = .970 MTPM, P = .730 tilt). The amount of change in tibial slope was also not associated with migration or inducible displacement. CONCLUSIONS: Residual and change in postoperative tibial slope were not associated with implant migration into tilt or overall migration, or inducible displacement for a single implant design. These findings support positioning tibial implants in a range of slopes, which may support patient-specific approaches to implant alignment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeTibiaKnee ProsthesisProsthesis FailureRadiostereometric AnalysisProsthesis DesignHumansFemaleMaleAgedMiddle AgedAged, 80 and overKnee JointBone CementsForeign-Body Migration

Stichwörter der Autor:innen

alignmentimplant migrationradiostereometric analysistibial slopetotal knee arthroplasty

Substanzen

Bone Cements

Autor:innen und Institutionen

  • Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
  • Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada; Mechanical and Materials Engineering, Queen's University…

Förderung

  • Atlantic Canada Opportunities Agency
  • Canadian Orthopaedic Foundation

Zitieren

APA

Richardson, G., Kivell, M. J., Dunbar, M. J., & Laende, E. K. (2024). Tibial Slope Is Not Associated With Implant Migration Following Cemented Total Knee Arthroplasty With a Single Implant Design. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2024.04.021

Vancouver

Richardson G, Kivell MJ, Dunbar MJ, Laende EK. Tibial Slope Is Not Associated With Implant Migration Following Cemented Total Knee Arthroplasty With a Single Implant Design. The Journal of Arthroplasty. 2024. doi:10.1016/j.arth.2024.04.021

BibTeX
@article{Richardson2024,
  author = {Richardson, Glen and Kivell, Matthew J and Dunbar, Michael J and Laende, Elise K},
  title = {Tibial Slope Is Not Associated With Implant Migration Following Cemented Total Knee Arthroplasty With a Single Implant Design},
  journal = {The Journal of Arthroplasty},
  year = {2024},
  doi = {10.1016/j.arth.2024.04.021}
}
Kostenlos starten →