EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Factors Influencing Noise Following Primary Ceramic-on-Ceramic Total Hip Arthroplasty

Yibin Zhang, Yuhang Gao, Yi Leng, Jianzeng Zhang, Chengshuai Zhang, Xin Qi

The Journal of Arthroplasty · 2024

DOI: 10.1016/j.arth.2023.08.027 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024. Verfasst von Yibin Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bone and Joint Surgery, Orthopedic Center, The First Hospital of Jilin University, Changchun, Jilin, China. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Developmental Dysplasia of the Hip. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The noise associated with ceramic-on-ceramic (CoC) total hip arthroplasty (THA) has been a concerning issue, while its underlying causes remain unclear. METHODS: We conducted a retrospective analysis of 119 patients (174 primary CoC THAs) who had a mean follow-up of 28 months (range, 12 to 106). A questionnaire was designed to collect information on nature, frequency, onset, duration, and impact of the noise. Postoperative x-rays were evaluated. Clinical evaluations, including Harris and Oxford hip scores, were documented at follow-up time points (6 weeks, 3 months, 6 months, and 1 year). RESULTS: Of the 174 hips, 31.6% reported noise, including 26 popping (14.9%), 24 clicking (12.1%), and 5 grinding (2.9%). No patients reported squeaking. Noisy hips had lower age (P = .009) and body mass index (P = .019). Among patients with developmental dysplasia of the hip, 17 of 55 hips reported noise associated with smaller cup anteversion angle (P = .004), greater body height (P = .022), and larger acetabular cup size (P = .049). Noise typically began at a mean of 193 days (range, 1 to 2,598) after surgery and disappeared spontaneously in 50.9% of hips before final follow-up, with an average disappearance time of 211 days (range, 60 to 730). Noise did not affect daily life in 74.5% of patients, while 26.9% of patients who had popping reported painful sensations. One patient experienced joint dislocation, and another experienced a ceramic liner fracture during follow-up. No statistical difference was observed in outcome scores between noise and silent groups at 4 follow-up time points. CONCLUSIONS: Incidence of noise after primary CoC THA is relatively high. Smaller cup anteversion and larger acetabular cup size were associated with noise production in patients who had developmental dysplasia of the hip.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisDevelopmental Dysplasia of the HipHumansRetrospective StudiesProsthesis FailureCeramicsProsthesis DesignTreatment OutcomeHip Joint

Stichwörter der Autor:innen

bearingceramic-on-ceramiccomplicationsdevelopmental dysplasia of the hipnoisetotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Bone and Joint Surgery, Orthopedic Center, The First Hospital of Jilin University, Changchun, Jilin, China.

Zitieren

APA

Zhang, Y., Gao, Y., Leng, Y., Zhang, J., Zhang, C., & Qi, X. (2024). Factors Influencing Noise Following Primary Ceramic-on-Ceramic Total Hip Arthroplasty. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2023.08.027

Vancouver

Zhang Y, Gao Y, Leng Y, Zhang J, Zhang C, Qi X. Factors Influencing Noise Following Primary Ceramic-on-Ceramic Total Hip Arthroplasty. The Journal of Arthroplasty. 2024. doi:10.1016/j.arth.2023.08.027

BibTeX
@article{Zhang2024,
  author = {Zhang, Yibin and Gao, Yuhang and Leng, Yi and Zhang, Jianzeng and Zhang, Chengshuai and Qi, Xin},
  title = {Factors Influencing Noise Following Primary Ceramic-on-Ceramic Total Hip Arthroplasty},
  journal = {The Journal of Arthroplasty},
  year = {2024},
  doi = {10.1016/j.arth.2023.08.027}
}
Kostenlos starten →