Fachartikel in der Zeitschrift International Orthopaedics, 2025. Verfasst von Makoto Kitade und 2 weiteren Autor:innen. Beteiligte Einrichtung: University of Fukui, Fukui, Japan. makoto8@u-fukui.ac.jp. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Prosthesis Design, Osteoarthritis, Hip. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Fukui.
Abstract (Originalsprache)
Background
Patients with secondary hip osteoarthritis due to developmental dysplasia of the hip (DDH) often have abnormal femoral morphology, making stem design critical for long-term outcomes. The FMS-anatomic stem previously demonstrated favourable mid-term results. Its successor, the Anatomic Fit stem, was developed with a reduced hydroxyapatite-coated area to enhance proximal load transfer and a narrower lateral flare to facilitate insertion. This study aimed to analyze the long-term clinical and radiographic outcomes of these stems.
Methods
The one-hundred seventy-eight hips underwent total hip arthroplasty using either the FMS-anatomic or Anatomic Fit stem. After applying exclusion criteria, 119 hips (36 FMS-anatomic and 83 Anatomic Fit) were analyzed. Clinical and radiographic outcomes were assessed, and stem survival was evaluated using Kaplan–Meier analysis with stem revision as the endpoint.
Results
The 15- and 20-year survival rates were 97.2% and 94.4% for the FMS-anatomic stem, and 98.8% for the Anatomic Fit stem at both time points, with no significant difference. Spot welds were observed in nearly all cases, but their distribution differed significantly: zones 2 and 6 in the FMS-anatomic group and zones 1 and 7 in the Anatomic Fit group ( P < 0.05). Stress shielding of Grade 3 or higher occurred in 16.5% of FMS-anatomic stems and 33.7% of Anatomic Fit stems ( P < 0.05).
Conclusions
Both stems showed excellent long-term survival and proximal fixation. However, the Anatomic Fit stem did not reduce stress shielding, despite its modified design intended to improve load transfer.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Fukui, Fukui, Japan. makoto8@u-fukui.ac.jp.
- University of Fukui, Fukui, Japan. tani.t.1026@gmail.com.
- Osaka University, Osaka, Japan. tani.t.1026@gmail.com.
- University of Fukui, Fukui, Japan.
Förderung
- University of Fukui
Zitieren
APA
Kitade, M., Tani, T., & Matsumine, A. (2025). Long-term results of the metaphyseal-loading anterolaterally flared anatomic femoral stem for total hip arthroplasty. International Orthopaedics. https://doi.org/10.1007/s00264-025-06624-y
Vancouver
Kitade M, Tani T, Matsumine A. Long-term results of the metaphyseal-loading anterolaterally flared anatomic femoral stem for total hip arthroplasty. International Orthopaedics. 2025. doi:10.1007/s00264-025-06624-y
BibTeX
@article{Kitade2025,
author = {Kitade, Makoto and Tani, Tetsuro and Matsumine, Akihiko},
title = {Long-term results of the metaphyseal-loading anterolaterally flared anatomic femoral stem for total hip arthroplasty},
journal = {International Orthopaedics},
year = {2025},
doi = {10.1007/s00264-025-06624-y}
}
EUVIMED