Safe Sex After Total Hip Arthroplasty: Using Computed Tomography-Based Robotics to Evaluate “At-Risk” Sexual Positions
The Journal of Arthroplasty · 2024-02 · 39 (2) · 433-440.e4
DOI: 10.1016/j.arth.2023.08.022 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024-02. Verfasst von Samuel D Stegelmann und 3 weiteren Autor:innen. Beteiligte Einrichtung: HCA Medical City Healthcare UNT-TCU GME (Denton), Denton, Texas. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 43 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Total hip arthroplasty (THA) can improve sexual satisfaction, but fear of dislocation can lead to sexual difficulties following this procedure. Previous kinematic research identified 4 sexual positions in women and 2 in men that were considered at risk for impingement. This study aimed to validate these findings using current robotic THA simulations. METHODS: The 3-dimensional renderings from 12 patients who received computed tomography (CT)-based robotic THA were used to assess for prosthetic and/or bony impingement among 12 popular sexual positions. There were 9 cup orientations tested for each position (a combination of anteversion [0 °, 15 °, and 30 °] and inclination [40 °, 45 °, and 60 °]). The at-risk positions were tested again using the unique hip positions and cup orientations where previous geometric modeling data found impingement to occur. RESULTS: Using mean hip positions, impingement occurred in at least 1 patient in 1 of the 12 positions for women (position 5) and 5 of the 12 positions for men (positions 1, 5, 8, 10, and 11). Among the at-risk positions, impingement occurred in none of the 2 at-risk women positions (0 of 17 cup orientations) and in both at-risk men positions (9 of 9 cup orientations for position 8 and 1 of 1 for position 11). CONCLUSION: Recreating popular and at-risk sexual positions following THA with a CT-based robotics system yielded results that were inconsistent with previous geometric modeling data. Resolving these discrepancies is crucial for surgeons to provide accurate postoperative patient education. The CT-based robotic systems may provide necessary input to feasibly individualize such recommendations, but current limitations in CT-based robotics require continued attention and innovation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- HCA Medical City Healthcare UNT-TCU GME (Denton), Denton, Texas.
- Department of Orthopedic Surgery, Mercy Health Saint Vincent Medical Center, Toledo, Ohio.
- Department of Orthopaedic Surgery, Marshall University, Joan C. Edwards School of Medicine, Huntington, West Virginia.
Zitieren
APA
Stegelmann, S. D., Butler, J. T., Hiatt, J. L., & Bullock, M. W. (2024). Safe Sex After Total Hip Arthroplasty: Using Computed Tomography-Based Robotics to Evaluate “At-Risk” Sexual Positions. The Journal of Arthroplasty, 39(2), 433-440.e4. https://doi.org/10.1016/j.arth.2023.08.022
Vancouver
Stegelmann SD, Butler JT, Hiatt JL, Bullock MW. Safe Sex After Total Hip Arthroplasty: Using Computed Tomography-Based Robotics to Evaluate “At-Risk” Sexual Positions. The Journal of Arthroplasty. 2024;39(2):433-440.e4. doi:10.1016/j.arth.2023.08.022
BibTeX
@article{Stegelmann2024,
author = {Stegelmann, Samuel D and Butler, Justin T and Hiatt, John L and Bullock, Matthew W},
title = {Safe Sex After Total Hip Arthroplasty: Using Computed Tomography-Based Robotics to Evaluate “At-Risk” Sexual Positions},
journal = {The Journal of Arthroplasty},
year = {2024},
volume = {39},
number = {2},
pages = {433--440.e4},
doi = {10.1016/j.arth.2023.08.022}
}
EUVIMED