EUVIMEDEUVIMED entdecken
Crossref

Changes in Center of Rotation and Offsets With Teardrop‐Landmark Acetabular Cup Positioning: A Computed Tomography Simulation Analysis

Veränderungen von Rotationszentrum und Offsets bei Acetabulum-Kappenpositionierung am Teardrop-Landmark: CT-Simulationsanalyse

Shigeo Hagiwara iD, Junichi Nakamura iD, Yuya Kawarai iD, Rui Hirasawa iD, Kazuhide Inage iD, Seiji Ohtori iD

Journal of Orthopaedic Research · 2026-01 · 44 (1)

DOI: 10.1002/jor.70117 ↗

Auf einen Blick

In 60 Hüften zeigte die teardrop-basierte Acetabulum-Kappenpositionierung eine mediale und superiore Verschiebung des Hüftrotationszentrums. AO und FO nahmen ab, VO nahm zu.

Fragestellung

Wie verändern sich Rotationszentrum und Offsets bei teardrop-basierter Positionierung der Acetabulum-Kappe in der THA?

Methode

CT-basierte Simulationsstudie an 60 Hüften; die kontralaterale unauffällige Hüfte diente als Kontrolle.

Ergebnisse

Im Vergleich zur kontralateralen Seite waren AO und FO signifikant reduziert und VO signifikant erhöht (p < 0,01). Das COR verschob sich in beiden Gruppen medial und superior (2,7–2,8 mm bzw. 2,0–2,8 mm).

Schlussfolgerung der Autor:innen

Die teardrop-basierte Positionierung der Acetabulum-Kappe führt zu einer medialen und superioren Verschiebung des COR und reduziert AO und GO. Bei Arthrose ist zusätzlich FO vermindert, was GO weiter beeinträchtigt.

Kernaussagen

  • AO und FO sanken, VO stieg auf der operierten Seite
  • COR-Verschiebung: 2,7–2,8 mm medial, 2,0–2,8 mm superior
  • Bei Arthrose verringerte sich GO um 4,7 mm

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Research, online erschienen am 21.12.2025. Verfasst von Shigeo Hagiwara und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan. Hauptthemen laut MEDLINE: Acetabulum, Arthroplasty, Replacement, Hip, Hip Joint, Hip Prosthesis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Restoration of the hip center of rotation (COR) is a primary goal in total hip arthroplasty (THA). Although the teardrop has been widely used as a reference for acetabular cup positioning, its effect on offsets remains uncertain. We conducted a computed tomography–based simulation study of 60 hips (30 osteoarthritis, 30 osteonecrosis of the femoral head) undergoing THA. The contralateral, unaffected hip served as the control. The acetabular cup was positioned just lateral to the teardrop, aligned with the true floor of the acetabulum using preoperative templating software. Acetabular, femoral, and vertical offsets (AO, FO, and VO) were measured bilaterally, and the horizontal and vertical displacements of the COR were evaluated. Compared to the contralateral unaffected side, AO and FO significantly decreased and VO significantly increased on the surgical side ( p < 0.01). The COR shifted medially and superiorly in both OA and ONFH groups (average: 2.7–2.8 mm medial, 2.0–2.8 mm superior). In the OA group, global offset (GO), the sum of AO and FO, decreased by 4.7 mm due to a significant reduction in FO. Teardrop‐based positioning of the acetabular cup results in medial and superior displacement of the COR, consequently reducing AO and GO. In patients with osteoarthritis, a decreased FO further compromises GO, making femoral component adjustment essential for biomechanical restoration. Further investigation into the clinical ramifications of these offset changes is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AcetabulumArthroplasty, Replacement, HipHip JointHip ProsthesisHumansMiddle AgedMaleFemaleTomography, X-Ray ComputedAgedAdultRotationOsteoarthritis, HipFemur Head Necrosis

Stichwörter der Autor:innen

acetabular offsetcenter of rotationglobal offsettotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.

ORCID-Profile: Shigeo Hagiwara, Junichi Nakamura, Yuya Kawarai, Rui Hirasawa, Kazuhide Inage, Seiji Ohtori

Zitieren

APA

Hagiwara, S., Nakamura, J., Kawarai, Y., Hirasawa, R., Inage, K., & Ohtori, S. (2026). Changes in Center of Rotation and Offsets With Teardrop‐Landmark Acetabular Cup Positioning: A Computed Tomography Simulation Analysis. Journal of Orthopaedic Research, 44(1). https://doi.org/10.1002/jor.70117

Vancouver

Hagiwara S, Nakamura J, Kawarai Y, Hirasawa R, Inage K, Ohtori S. Changes in Center of Rotation and Offsets With Teardrop‐Landmark Acetabular Cup Positioning: A Computed Tomography Simulation Analysis. Journal of Orthopaedic Research. 2026;44(1). doi:10.1002/jor.70117

BibTeX
@article{Hagiwara2026,
  author = {Hagiwara, Shigeo and Nakamura, Junichi and Kawarai, Yuya and Hirasawa, Rui and Inage, Kazuhide and Ohtori, Seiji},
  title = {Changes in Center of Rotation and Offsets With Teardrop‐Landmark Acetabular Cup Positioning: A Computed Tomography Simulation Analysis},
  journal = {Journal of Orthopaedic Research},
  year = {2026},
  volume = {44},
  number = {1},
  doi = {10.1002/jor.70117}
}
Kostenlos starten →