Are Kinematics an Indicator of Outcome After Total Knee Arthroplasty?
The Journal of Arthroplasty · 2024-02 · 39 (2) · 343-349.e1
DOI: 10.1016/j.arth.2023.08.010 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024-02. Verfasst von Phillipa E Hodge und 5 weiteren Autor:innen. Beteiligte Einrichtung: The Trauma and Orthopaedic Research Unit, Canberra Hospital, Canberra, ACT, Australia; Medical School, Australian National University, Canberra, ACT,…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Osteoarthritis, Knee. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: A proportion of total knee arthroplasty (TKA) patients are dissatisfied postoperatively, particularly with their ability to perform higher-demand activities including deep-kneeling and step-up where kinematic parameters are more demanding. The purpose of this study was to examine the relationship between knee kinematics of step-up and deep-kneeling and patient-reported outcome measures following TKA. METHODS: Sixty-four patients were included at minimum 1-year follow-up. Participants performed a step-up and deep-kneeling task which was imaged via single-plane fluoroscopy. 3-dimensional prosthesis computer-aided design models were registered to the fluoroscopy, yielding in-vivo kinematic data. Associations between kinematics and patient-reported outcome measures, including Oxford Knee Score, American Knee Society Score, surgical satisfaction, and pain were assessed using log-transformed step-wise linear regressions. RESULTS: A higher total Oxford Knee Score was associated with more external rotation and more adduction at maximal flexion during kneeling and more external rotation and minimum flexion during step-up. Improved American Knee Society Score was associated with increased internal-external rotation during step-up. Improved surgical satisfaction was associated with greater maximum flexion and more external rotation at maximal flexion during deep-kneeling and more femoral internal rotation at terminal extension during step-up. An improved pain score was associated with greater maximum flexion and more femoral external rotation during deep-kneeling, as well as greater internal femoral rotation during step-up. CONCLUSION: The ability to move through full flexion/extension range and end-of-range rotation is important kinematic parameters that influence patient-reported outcome measures. Implant designs and postoperative rehabilitation should continue to focus on achieving these kinematic targets for enhanced outcomes after TKA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Trauma and Orthopaedic Research Unit, Canberra Hospital, Canberra, ACT, Australia; Medical School, Australian National University, Canberra, ACT, Australia.
- The Trauma and Orthopaedic Research Unit, Canberra Hospital, Canberra, ACT, Australia; Faculty of Health, University of Canberra, Canberra, ACT, Australia.
Zitieren
APA
Hodge, P. E., Rabak, O. J., Perriman, D. M., Scarvell, J. M., Smith, P. N., & Lynch, J. T. (2024). Are Kinematics an Indicator of Outcome After Total Knee Arthroplasty?. The Journal of Arthroplasty, 39(2), 343-349.e1. https://doi.org/10.1016/j.arth.2023.08.010
Vancouver
Hodge PE, Rabak OJ, Perriman DM, Scarvell JM, Smith PN, Lynch JT. Are Kinematics an Indicator of Outcome After Total Knee Arthroplasty?. The Journal of Arthroplasty. 2024;39(2):343-349.e1. doi:10.1016/j.arth.2023.08.010
BibTeX
@article{Hodge2024,
author = {Hodge, Phillipa E and Rabak, Owen J and Perriman, Diana M and Scarvell, Jennie M and Smith, Paul N and Lynch, Joseph T},
title = {Are Kinematics an Indicator of Outcome After Total Knee Arthroplasty?},
journal = {The Journal of Arthroplasty},
year = {2024},
volume = {39},
number = {2},
pages = {343--349.e1},
doi = {10.1016/j.arth.2023.08.010}
}
EUVIMED