The Stability of Fixation of Vancouver B2 Periprosthetic Femoral Fractures: Effect of Implantation Technique
The Journal of Arthroplasty · 2023
DOI: 10.1016/j.arth.2023.03.008 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2023. Verfasst von Robert Frangie und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, University of Texas Health Science Center at Houston, Bellaire, Texas. Hauptthemen laut MEDLINE: Hip Prosthesis, Arthroplasty, Replacement, Hip, Periprosthetic Fractures, Femoral Fractures. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: American Association of Hip and Knee Surgeons.
Abstract (Originalsprache)
BACKGROUND: Due to increasing volume of total hip arthroplasties, periprosthetic femoral fractures have become a common complication with increased revision burden and perioperative morbidity. The objective of this study was to evaluate the fixation stability of Vancouver B2 fractures treated with 2 techniques. METHODS: A common B2 fracture was created by reviewing 30 type B2 cases. The fracture was then reproduced in 7 pairs of cadaveric femora. The specimens were divided into 2 groups. In Group I ("reduce-first"), the fragments were reduced first, followed by implantation of a tapered fluted stem. In Group II ("ream-first"), the stem was implanted in the distal femur first, followed by fragment reduction and fixation. Each specimen was loaded in a multiaxial testing frame with 70% of peak load during walking. A motion capture system was used to track the motion of the stem and fragments. RESULTS: The average stem diameter in Group II was 16.1 ± 0.4 mm, versus 15.4 ± 0.5 mm in Group I. The fixation stability was not significantly different in the 2 groups. After the testing, the average stem subsidence was 0.36 ± 0.31 mm and 0.19 ± 0.14 mm (P = .17) and the average rotation was 1.67 ± 1.30° and 0.91 ± 1.11° (P = .16) in Groups I and II, respectively. Compared to the stem, there was less motion of the fragments and there was no difference between the 2 groups (P > .05). CONCLUSIONS: When tapered fluted stems were used in combination with cerclage cables for treatment of Vancouver type B2 periprosthetic femoral fractures, both the "reduce-first" and "ream-first" techniques showed adequate stem and fracture stability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, University of Texas Health Science Center at Houston, Bellaire, Texas.
Förderung
- American Association of Hip and Knee Surgeons
Zitieren
APA
Frangie, R., Han, S., Noble, P. C., Gold, J. E., Lanfermeijer, N. D., Reddy, K. I., Ismaily, S. K., Su, J., Schroder, S. J., & Rodriguez-Quintana, D. (2023). The Stability of Fixation of Vancouver B2 Periprosthetic Femoral Fractures: Effect of Implantation Technique. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2023.03.008
Vancouver
Frangie R, Han S, Noble PC, Gold JE, Lanfermeijer ND, Reddy KI, et al. The Stability of Fixation of Vancouver B2 Periprosthetic Femoral Fractures: Effect of Implantation Technique. The Journal of Arthroplasty. 2023. doi:10.1016/j.arth.2023.03.008
BibTeX
@article{Frangie2023,
author = {Frangie, Robert and Han, Shuyang and Noble, Philip C and Gold, Jonathan E and Lanfermeijer, Nicholas D and Reddy, Kartik I and Ismaily, Sabir K and Su, Jacob and Schroder, Steven J and Rodriguez-Quintana, David},
title = {The Stability of Fixation of Vancouver B2 Periprosthetic Femoral Fractures: Effect of Implantation Technique},
journal = {The Journal of Arthroplasty},
year = {2023},
doi = {10.1016/j.arth.2023.03.008}
}
EUVIMED