Long-Term Outcomes of Cementing Highly Cross-Linked Polyethylene Liners Into Well-Fixed Acetabular Shells in Revision Total Hip Arthroplasty
The Journal of Arthroplasty · 2023
DOI: 10.1016/j.arth.2023.01.028 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2023. Verfasst von Kyungjun Cho und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Osteolysis, Hip Prosthesis. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 35 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Cementing a new liner into a secure, well-positioned metallic shell can be a less-invasive strategy in revision total hip arthroplasty (THA). This study aimed to report the mean 14-year outcomes of cementing highly cross-linked polyethylene (XLPE) liners into well-fixed acetabular shells in revision THAs. METHODS: This study reviewed a single-surgeon series of cementing XLPE liners into well-fixed acetabular components. Of the 52 hips (51 patients) evaluated, 48 hips (47 patients) that satisfied a minimum follow-up of 10 years were included. The Harris Hip score was used for clinical evaluation. Final hip radiographs were used to determine the extent of acetabular osteolysis and stability of the components. The mean age at index operation was 53 years (range, 32 to 72). The mean follow-up duration was 14 years (range, 10 to 18). RESULTS: The mean Harris Hip score improved from 58 points (range, 23-81) preoperatively to 91 points (range, 45-100) at the final evaluation (P < .001). A total of 3 acetabular rerevisions were performed, all for aseptic loosening of the outer shell. One postoperative dislocation occurred, but it was successfully treated with a closed reduction. Final radiographs showed a significant reduction in acetabular osteolysis (P < .001). Implant survivorship free from any rerevision was 93.3% (95% confidence interval, 85.9-100%) at 14 years. CONCLUSION: Cementing an XLPE liner into a well-fixed acetabular shell in revision THA demonstrated excellent clinical and radiographic outcomes at a mean of 14 years postoperatively. This technique could be a safe and durable option in the absence of XLPE liners compatible with preimplanted shells.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
- Department of Orthopedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea.
Zitieren
APA
Cho, K., Park, C. W., Jeong, S. J., Lee, J. H., Lim, S. J., & Park, Y. S. (2023). Long-Term Outcomes of Cementing Highly Cross-Linked Polyethylene Liners Into Well-Fixed Acetabular Shells in Revision Total Hip Arthroplasty. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2023.01.028
Vancouver
Cho K, Park CW, Jeong SJ, Lee JH, Lim SJ, Park YS. Long-Term Outcomes of Cementing Highly Cross-Linked Polyethylene Liners Into Well-Fixed Acetabular Shells in Revision Total Hip Arthroplasty. The Journal of Arthroplasty. 2023. doi:10.1016/j.arth.2023.01.028
BibTeX
@article{Cho2023,
author = {Cho, Kyungjun and Park, Chan-Woo and Jeong, Sang Jin and Lee, Jong-Hyun and Lim, Seung-Jae and Park, Youn-Soo},
title = {Long-Term Outcomes of Cementing Highly Cross-Linked Polyethylene Liners Into Well-Fixed Acetabular Shells in Revision Total Hip Arthroplasty},
journal = {The Journal of Arthroplasty},
year = {2023},
doi = {10.1016/j.arth.2023.01.028}
}
EUVIMED