Is Highly Cross-Linked Polyethylene Safe for Use in High-Flexion Posterior Stabilized Total Knee Arthroplasty?
The Journal of Arthroplasty · 2023-02 · 38 (2) · 286-292
DOI: 10.1016/j.arth.2022.08.025 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2023-02. Verfasst von Young-Hoo Kim und 3 weiteren Autor:innen. Beteiligte Einrichtung: The Joint Replacement Center of Seoul Metropolitan SeoNam Hospital, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Fractures, Bone. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 50 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Application of highly cross-linked polyethylene (HXLPE) to a posterior cruciate-substituting total knee arthroplasty (TKA) might add the risk of fracture and failure of the tibial polyethylene insert. The purpose of this study is to evaluate the long-term (up to 19 years) clinical and radiographic results of posterior cruciate-substituting TKAs with HXLPE or conventional polyethylene. METHODS: This study analyzed the results of 1,217 patients (444 men and 773 women; mean age of 65 ± 7 years, range, 31-85) (2,434 knees) who had received a NexGen LPS-Flex prosthesis with a conventional tibial insert in one knee and the same prosthesis with an HXLPE tibial insert in the contralateral knee. The mean duration of follow-up was 17 years (range, 15-19). RESULTS: The 2 groups did not differ significantly (P > .05) with regard to the clinical and radiographic results. No knee in either group had a fracture of the tibial polyethylene post or failure of the locking mechanism of the tibial polyethylene insert or osteolysis. Twenty-eight knees (2.3%) in the HXLPE group and 26 knees (2.1%) in the conventional polyethylene group were revised. The estimated survival rate at 17 years was 97.7% in the HXLPE group and 97.9% in the conventional polyethylene group. CONCLUSION: The data suggest that clinical and radiographic findings at a mean of 17 years after posterior cruciate-substituting TKA are the same for patients treated with HXLPE and those treated with conventional polyethylene.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- The Joint Replacement Center of Seoul Metropolitan SeoNam Hospital, Seoul, Republic of Korea.
- Department of Orthopeadic Surgery, Ewha Womans University, Seoul Hospital, Seoul, Republic of Korea.
Zitieren
APA
Kim, Y. H., Park, J. W., Jang, Y. S., & Kim, E. J. (2023). Is Highly Cross-Linked Polyethylene Safe for Use in High-Flexion Posterior Stabilized Total Knee Arthroplasty?. The Journal of Arthroplasty, 38(2), 286-292. https://doi.org/10.1016/j.arth.2022.08.025
Vancouver
Kim YH, Park JW, Jang YS, Kim EJ. Is Highly Cross-Linked Polyethylene Safe for Use in High-Flexion Posterior Stabilized Total Knee Arthroplasty?. The Journal of Arthroplasty. 2023;38(2):286-292. doi:10.1016/j.arth.2022.08.025
BibTeX
@article{Kim2023,
author = {Kim, Young-Hoo and Park, Jang-Won and Jang, Young-Soo and Kim, Eun-Jung},
title = {Is Highly Cross-Linked Polyethylene Safe for Use in High-Flexion Posterior Stabilized Total Knee Arthroplasty?},
journal = {The Journal of Arthroplasty},
year = {2023},
volume = {38},
number = {2},
pages = {286--292},
doi = {10.1016/j.arth.2022.08.025}
}
EUVIMED