EUVIMEDEUVIMED entdecken
Crossref

Validity and Reliability of Upper Limb Kinematic Assessment Using a Markerless Motion Capture (MMC) System: A Pilot Study

Winnie W T Lam, Kenneth N K Fong

Archives of Physical Medicine and Rehabilitation · 2024-04 · 105 (4) · 673-681.e2

DOI: 10.1016/j.apmr.2023.10.018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Physical Medicine and Rehabilitation, 2024-04. Verfasst von Winnie W T Lam und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR. Electronic address: wing-tung-winnie.lam@connect…. Hauptthemen laut MEDLINE: Motion Capture, Upper Extremity. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: University Grants Committee Research Grants Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To investigate the validity and test-retest reliability of a customized markerless motion capture (MMC) system that used iPad Pros with a Light Detection And Ranging scanner at two different viewing angles to measure the active range of motion (AROM) and the angular waveform of the upper-limb-joint angles of healthy adults performing functional tasks. DESIGN: Participants were asked to perform shoulder and elbow actions for the investigator to take AROM measurements, followed by four tasks that simulated daily functioning. Each participant attended 2 experimental sessions, which were held at least 2 days and at most 14 days apart. SETTING: A Vicon system and 2 iPad Pros installed with our MMC system were placed at 2 different angles to the participants and recorded their movements concurrently during each task. PARTICIPANTS: Thirty healthy adults (mean age: 28.9, M/F ratio: 40/60). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: The AROM and the angular waveform of the upper-limb-joint angles. RESULTS: The iPad Pro MMC system underestimated the shoulder joint and elbow joint angles in all four simulated functional tasks. The MMC demonstrated good to excellent test-retest reliability for the shoulder joint AROM measurements in all 4 tasks. CONCLUSIONS: The maximal AROM measurements calculated by the MMC system had consistently smaller values than those measured by the goniometer. An MMC in iPad Pro system might not be able to replace conventional goniometry for clinical ROM measurements, but it is still suggested for use in home-based and telerehabilitation training for intra-subject measurements because of its good reliability, low cost, and portability. Further development to improve its performance in motion capture and analysis in disease populations is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Motion CaptureUpper ExtremityAdultHumansPilot ProjectsBiomechanical PhenomenaReproducibility of ResultsRange of Motion, Articular

Stichwörter der Autor:innen

KinematicMarkerless motion captureRange of motionRehabilitationUpper limbValidity

Autor:innen und Institutionen

  • Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR. Electronic address: wing-tung-winnie.lam@connect.polyu.hk.
  • Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR.

Förderung

  • University Grants Committee Research Grants Council

Zitieren

APA

Lam, W. W. T., & Fong, K. N. K. (2024). Validity and Reliability of Upper Limb Kinematic Assessment Using a Markerless Motion Capture (MMC) System: A Pilot Study. Archives of Physical Medicine and Rehabilitation, 105(4), 673-681.e2. https://doi.org/10.1016/j.apmr.2023.10.018

Vancouver

Lam WWT, Fong KNK. Validity and Reliability of Upper Limb Kinematic Assessment Using a Markerless Motion Capture (MMC) System: A Pilot Study. Archives of Physical Medicine and Rehabilitation. 2024;105(4):673-681.e2. doi:10.1016/j.apmr.2023.10.018

BibTeX
@article{Lam2024,
  author = {Lam, Winnie W T and Fong, Kenneth N K},
  title = {Validity and Reliability of Upper Limb Kinematic Assessment Using a Markerless Motion Capture (MMC) System: A Pilot Study},
  journal = {Archives of Physical Medicine and Rehabilitation},
  year = {2024},
  volume = {105},
  number = {4},
  pages = {673--681.e2},
  doi = {10.1016/j.apmr.2023.10.018}
}
Kostenlos starten →