EUVIMEDEUVIMED entdecken
Crossref

Reliability, Concurrent Validity, and Minimal Detectable Change of the Hand-Held Dynamometry for the Assessment of Knee Muscle Strength in Patients With Revision Total Knee Arthroplasty

Musa Eymir, Bayram Unver, Vasfi Karatosun

Archives of Physical Medicine and Rehabilitation · 2024

DOI: 10.1016/j.apmr.2023.05.002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Physical Medicine and Rehabilitation, 2024. Verfasst von Musa Eymir und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Erzurum Technical University, Yakutiye-Erzurum, Turkey. Electronic addres…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To determine the concurrent validity, reliability, and minimal detectable change (MDC) of the hand-held dynamometry (HHD) for knee strength measurement in patients with revision total knee arthroplasty (r-TKA). DESIGN: A reliability and validity analysis. SETTING: Orthopedic and physical therapy services of university hospital. PARTICIPANTS: The study included 42 patients with r-TKA (N=42). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Knee muscle strength assessments were performed by 2 physiotherapists in 3 different sessions by using HHD. Participants were instructed to exert a maximal force for lasting 5 seconds against HHD. The first examiner performed the strength testing, and after 30-minutes rest, the second examiner performed the same procedure for inter-examiner reliability. One hour after the initial testing, the first examiner reperformed the strength testing for intra-examiner reliability. The correlations of the knee extensors and knee flexors strength with 50-foot walking test and 30-second chair stand test were assessed for concurrent validity. RESULTS: The inter-examiner reliabilities of knee extensors and flexors strength measurements were 0.97 and 0.95, respectively. The SEM and the minimal detectable changes at 95% confidence level (MDC95) for knee extensors were 10.39 and 28.65 Newton-meters (Nm), and SEM and MDC95 for knee flexors were 8.70 and 23.99 Nm, respectively. The intra-examiner reliabilities of knee extensors and flexors strength measurements were 0.96. SEM and MDC95 for knee extensors were 12.00 and 33.09 Nm, and SEM and MDC95 for knee flexors were 7.78 and 21.45 Nm, respectively. The knee muscle strength showed strong significant correlations with physical performance tests (all, P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeHumansReproducibility of ResultsIsometric ContractionMuscle Strength DynamometerMuscle StrengthMuscle, Skeletal

Stichwörter der Autor:innen

Hand-held dynamometryRehabilitationReliabilityRevision total knee arthroplastyStrength assessmentValidity

Autor:innen und Institutionen

  • Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Erzurum Technical University, Yakutiye-Erzurum, Turkey. Electronic address: fztmusaeymir@hotmail.com.
  • Faculty of Physical Therapy and Rehabilitation, Dokuz Eylul University, Balçova-Izmir, Turkey.
  • Department of Orthopaedics and Traumatology, School of Medicine, Dokuz Eylul University, Balçova-Izmir, Turkey.

Zitieren

APA

Eymir, M., Unver, B., & Karatosun, V. (2024). Reliability, Concurrent Validity, and Minimal Detectable Change of the Hand-Held Dynamometry for the Assessment of Knee Muscle Strength in Patients With Revision Total Knee Arthroplasty. Archives of Physical Medicine and Rehabilitation. https://doi.org/10.1016/j.apmr.2023.05.002

Vancouver

Eymir M, Unver B, Karatosun V. Reliability, Concurrent Validity, and Minimal Detectable Change of the Hand-Held Dynamometry for the Assessment of Knee Muscle Strength in Patients With Revision Total Knee Arthroplasty. Archives of Physical Medicine and Rehabilitation. 2024. doi:10.1016/j.apmr.2023.05.002

BibTeX
@article{Eymir2024,
  author = {Eymir, Musa and Unver, Bayram and Karatosun, Vasfi},
  title = {Reliability, Concurrent Validity, and Minimal Detectable Change of the Hand-Held Dynamometry for the Assessment of Knee Muscle Strength in Patients With Revision Total Knee Arthroplasty},
  journal = {Archives of Physical Medicine and Rehabilitation},
  year = {2024},
  doi = {10.1016/j.apmr.2023.05.002}
}
Kostenlos starten →