EUVIMEDEUVIMED entdecken
Crossref

Determining the effects of AR/VR HMD design parameters (mass and inertia) on cervical spine joint torques

Amanda N Astrologo, Sarah Nano, Elizabeth M Klemm, Sandra J Shefelbine, Jack T Dennerlein

Applied Ergonomics · 2024

DOI: 10.1016/j.apergo.2023.104183 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Ergonomics, 2024. Verfasst von Amanda N Astrologo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, Northeastern University, Boston, MA, USA. Hauptthemen laut MEDLINE: Augmented Reality. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to determine gravitational and dynamic torques and muscle activity of the neck across a series of design parameters of head mounted displays (mass, center of mass, and counterweights) associated with virtual and augmented reality (VR/AR). Twenty young adult participants completed five movement types (Slow and Fast Flexion/Extension and Rotation, and Search) while wearing a custom-designed prototype headset that varied the three design parameters: display mass (0, 200, 500, and 750 g), distance of the display's center of mass in front of the eyes (approximately 1, 3, and 5 cm anteriorly), and counterweights of 0, 166, 332, and 500 g to balance the display mass of 500 g at 7 cm. Inverse dynamics of a link segment model of the head and headset provided estimates of the torques about the joint between the skull and the occiput-first cervical vertebrae (OC1) and joint between the C7 and T1 vertebrae (C7). Surface electromyography (EMG) measured bilateral muscle activity of the splenius and upper trapezius muscles. Adding 750 g of display mass nearly doubled root mean square joint torques across all movement types. Increasing the distance of the display mass in front of the eyes by 4 cm increased torques about OC1 for the Slow and Fast Rotation and Search movements by approximately 20%. Adding a counterweight decreased torques about OC1 during the rotation and search tasks but did not decrease the torques experienced in the lower cervical spine (C7). For the flexion/extension axis, the magnitude of the dynamic torque component was 20% or less of the total torque experienced whereas for the rotation axis the magnitude of the dynamic torque component was greater than 50% of the total torque. Surface EMG root mean square values significantly varied across movement types with the fast rotation having the largest values; however, they did not vary significantly across the headset configurations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Augmented RealityHumansTorqueJointsMovementCervical VertebraeBiomechanical Phenomena

Stichwörter der Autor:innen

ErgonomicsInjury preventionNeck biomechanics

Autor:innen und Institutionen

  • Department of Bioengineering, Northeastern University, Boston, MA, USA.
  • Department of Bioengineering, Northeastern University, Boston, MA, USA; Department of Mechanical & Industrial Engineering, Northeastern University, Boston, MA, USA.
  • Sargent College of Health and Rehabilitation Sciences, Boston University, Boston, MA, USA. Electronic address: jax@bu.edu.

Zitieren

APA

Astrologo, A. N., Nano, S., Klemm, E. M., Shefelbine, S. J., & Dennerlein, J. T. (2024). Determining the effects of AR/VR HMD design parameters (mass and inertia) on cervical spine joint torques. Applied Ergonomics. https://doi.org/10.1016/j.apergo.2023.104183

Vancouver

Astrologo AN, Nano S, Klemm EM, Shefelbine SJ, Dennerlein JT. Determining the effects of AR/VR HMD design parameters (mass and inertia) on cervical spine joint torques. Applied Ergonomics. 2024. doi:10.1016/j.apergo.2023.104183

BibTeX
@article{Astrologo2024,
  author = {Astrologo, Amanda N and Nano, Sarah and Klemm, Elizabeth M and Shefelbine, Sandra J and Dennerlein, Jack T},
  title = {Determining the effects of AR/VR HMD design parameters (mass and inertia) on cervical spine joint torques},
  journal = {Applied Ergonomics},
  year = {2024},
  doi = {10.1016/j.apergo.2023.104183}
}
Kostenlos starten →