Assessment of sequential distalization with aligners using cone-beam computed tomography merged with intraoral scans
American Journal of Orthodontics and Dentofacial Orthopedics · 2026-11
DOI: 10.1016/j.ajodo.2026.08.016 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Orthodontics and Dentofacial Orthopedics, 2026-11. Verfasst von Sanghee Lee und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, University of Washington, Seattle, Wash. Electronic address: slee1119@uw.edu. Die Arbeit nennt 40 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Sequential distalization with clear aligners, supplemented by Class II elastics, is commonly used to treat mild-to-moderate Class II malocclusions. Although favorable clinical outcomes have been reported, the underlying mechanism of tooth movement remains incompletely understood because of the methodologic limitations of conventional analyses. METHODS: This retrospective study included 30 adults treated with Invisalign sequential distalization combined with Class II elastics. Pretreatment and posttreatment cone-beam computed tomography images and intraoral scans were merged using segmentation and registration software. The fused models were superimposed on stable maxillary structures with computer-aided design/computer-aided manufacturing software, and the movement of the maxillary first molars was quantified in 3 planes of space using a 3-dimensional coordinate system. RESULTS: The mesiobuccal cusp tip of the maxillary first molar moved distally by a mean of 1.75 mm, whereas the mesiobuccal root apex moved distally by only 0.35 mm, representing 69.7% and 27.6% of the planned movement, respectively. The achieved distal crown tipping (7.14°) significantly exceeded the planned value, whereas the mesial-out rotation (8.22°) was only slightly greater than planned. CONCLUSIONS: In patients treated with sequential distalization and Class II elastics, maxillary first molar distalization occurred primarily through distal crown tipping and mesial-out rotation. Cone-beam computed tomography- intraoral scan fused models enabled precise 3-dimensional assessments of these tooth movements.
Autor:innen und Institutionen
- Department of Orthodontics, University of Washington, Seattle, Wash. Electronic address: slee1119@uw.edu.
- Fukuoka MA Orthodontics, Fukuoka, Japan.
- Private practice, Tokyo, Japan.
- Division of Orthodontics and Department of Biomedical Engineering, Faculty of Medicine and Dentistry, Mike Petryk School of Dentistry, University of Alberta, Edmonton, Alberta, Canada.
- Department of Orthodontics, University of Washington, Seattle, Wash.
Zitieren
APA
Lee, S., Minamidate, T., Watabe, H., Masuoka, N., El-Bialy, T., & Huang, G. J. (2026). Assessment of sequential distalization with aligners using cone-beam computed tomography merged with intraoral scans. American Journal of Orthodontics and Dentofacial Orthopedics. https://doi.org/10.1016/j.ajodo.2026.08.016
Vancouver
Lee S, Minamidate T, Watabe H, Masuoka N, El-Bialy T, Huang GJ. Assessment of sequential distalization with aligners using cone-beam computed tomography merged with intraoral scans. American Journal of Orthodontics and Dentofacial Orthopedics. 2026. doi:10.1016/j.ajodo.2026.08.016
BibTeX
@article{Lee2026,
author = {Lee, Sanghee and Minamidate, Takao and Watabe, Hiroyuki and Masuoka, Naoya and El-Bialy, Tarek and Huang, Greg J},
title = {Assessment of sequential distalization with aligners using cone-beam computed tomography merged with intraoral scans},
journal = {American Journal of Orthodontics and Dentofacial Orthopedics},
year = {2026},
doi = {10.1016/j.ajodo.2026.08.016}
}
EUVIMED