EUVIMEDEUVIMED entdecken
Crossref

Biomechanical effects of attachment designs on maxillary molar expansion with clear aligners: A 3-dimensional finite elements analysis using a single patient model

Irem Sensoy, Banu Kilic, Gokmen Kurt

American Journal of Orthodontics and Dentofacial Orthopedics · 2026-08 · 170 (2) · 182-194

DOI: 10.1016/j.ajodo.2026.02.015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Orthodontics and Dentofacial Orthopedics, 2026-08. Verfasst von Irem Sensoy und 2 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Orthodontics, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, Turkey. Electronic address: dt.iremsensoy@gmail.com. Hauptthemen laut MEDLINE: Finite Element Analysis, Molar, Orthodontic Appliance Design, Palatal Expansion Technique. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Bezmialem Vakıf Üniversitesi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION The aim of this study is to determine, using finite element analysis (FEA), attachment configurations that minimize adverse biomechanical effects on the molars during posterior expansion with clear aligners and support biomechanical interpretation for treatment planning. Using FEA, the Invisalign G8 protocol (Align Technology, San Jose, Calif) and conventional attachment designs were compared. METHODS Seven FEA models with attachments placed on the maxillary posterior teeth were created: (1) group 0: control group; (2) group 1: buccal horizontal rectangular attachment; (3) group 2: buccal gingivally-beveled rectangular attachment; (4) group 3: buccal-optimized expansion support attachment; (5) group 4: optimized attachment combined with an occlusally-beveled palatal attachment; (6) group 5: optimized attachment combined with a palatal horizontal rectangular attachment; and (7) group 6: palatal horizontal rectangular attachment without a buccal attachment. In the loading method, the deformation occurring in the clear aligner geometry and the contact forces resulting from the deformation were applied in the opposite direction. RESULTS In all groups, expansion was observed to occur in the form of buccal displacement of the crown and palatal displacement of the root. Optimized attachment configurations were associated with greater buccal crown displacement relative to palatal root displacement. In group 4, the highest expansion values and the lowest palatal root displacement were identified. CONCLUSIONS Simulation results indicated that parallel tooth displacement was not achieved with maxillary molar expansion using clear aligners, and buccal tipping predominated. Optimized attachments demonstrated a biomechanical tendency toward greater expansion efficiency. The combined use of optimized and palatal attachments showed increased buccal crown displacement with reduced palatal root displacement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Finite Element AnalysisMolarOrthodontic Appliance DesignPalatal Expansion TechniqueHumansBiomechanical PhenomenaMaxillaImaging, Three-DimensionalDental Stress AnalysisModels, Dental

Autor:innen und Institutionen

  • From the Department of Orthodontics, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, Turkey. Electronic address: dt.iremsensoy@gmail.com.
  • From the Department of Orthodontics, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, Turkey.

Förderung

  • Bezmialem Vakıf Üniversitesi

Zitieren

APA

Sensoy, I., Kilic, B., & Kurt, G. (2026). Biomechanical effects of attachment designs on maxillary molar expansion with clear aligners: A 3-dimensional finite elements analysis using a single patient model. American Journal of Orthodontics and Dentofacial Orthopedics, 170(2), 182-194. https://doi.org/10.1016/j.ajodo.2026.02.015

Vancouver

Sensoy I, Kilic B, Kurt G. Biomechanical effects of attachment designs on maxillary molar expansion with clear aligners: A 3-dimensional finite elements analysis using a single patient model. American Journal of Orthodontics and Dentofacial Orthopedics. 2026;170(2):182-194. doi:10.1016/j.ajodo.2026.02.015

BibTeX
@article{Sensoy2026,
  author = {Sensoy, Irem and Kilic, Banu and Kurt, Gokmen},
  title = {Biomechanical effects of attachment designs on maxillary molar expansion with clear aligners: A 3-dimensional finite elements analysis using a single patient model},
  journal = {American Journal of Orthodontics and Dentofacial Orthopedics},
  year = {2026},
  volume = {170},
  number = {2},
  pages = {182--194},
  doi = {10.1016/j.ajodo.2026.02.015}
}
Kostenlos starten →