Evaluation of the effect of different attachment configurations on molar teeth in maxillary expansion with clear aligners – a finite element analysis
BMC Oral Health · 2024
DOI: 10.1186/s12903-024-04544-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift BMC Oral Health, 2024. Verfasst von Nurver Karslı und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Dentistry, Department of Orthodontics, Karadeniz Technical University, Trabzon, Turkey. dtnurverkarsli@hotmail.com. Hauptthemen laut MEDLINE: Finite Element Analysis, Molar, Maxilla, Palatal Expansion Technique. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
OBJECTIVE: To evaluate the effects of different attachment configurations with and without buccal root torque on expansion movements achieved with aligners through finite element analysis (FEA). METHODS: FEA modelling was done with 0.25 mm buccal expansion force application to the maxillary molars with different attachment configurations: Eight models were tested (1) no attachment (NA), (2) horizontal attachment (HA), (3) gingivally beveled horizontal attachment (GHA), and (4) occlusally beveled horizontal attachment (OHA), as well as models with 6obuccal root torque, (5) no attachment (TNA), (6) horizontal attachment (THA), (7) gingivally beveled horizontal attachment (TGHA), and (8) occlusally beveled horizontal attachment (TOHA). RESULTS: The first and second molars exhibited buccal tipping in all models. The highest amount of buccal tipping for the molars was observed in the NA (6CMB, 0.232 mm; 6CMP, 0.246 mm; 7CMB, 0.281 mm; 7CMP, 0.312 mm) and GHA (6CMB, 0.230; 6CMP, 0.245; 7CMB, 0.279 mm; 7CMP, 0.311 mm) models, respectively, while the least tipping was observed in the TOHA model (6CMB, 0.155 mm; 6CMP, 0.168 mm; 7CMB, 0.216 mm; 7CMP, 0.240 mm). In all groups, the buccal tipping of the second molars was higher than that of the first molars. CONCLUSION: This FEA study showed that expansion with aligners tip maxillary molars buccally and the use of occlusally beveled attachments and addition of buccal root torque reduces uncontrolled buccal tipping.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Dentistry, Department of Orthodontics, Karadeniz Technical University, Trabzon, Turkey. dtnurverkarsli@hotmail.com.
- Faculty of Dentistry, Department of Orthodontics, Hacettepe University, Ankara, Turkey.
- Faculty of Dentistry, Department of Orthodontics, Karadeniz Technical University, Trabzon, Turkey.
- Tell Ortodonti Private Clinic, Ankara, Turkey.
- Faculty of Dentistry, Department of Orthodontics, The University of Sydney, Sydney, Australia.
Zitieren
APA
Karslı, N., Ocak, I., Akyıldız, M., Gögen, H., & Dalci, O. (2024). Evaluation of the effect of different attachment configurations on molar teeth in maxillary expansion with clear aligners – a finite element analysis. BMC Oral Health. https://doi.org/10.1186/s12903-024-04544-8
Vancouver
Karslı N, Ocak I, Akyıldız M, Gögen H, Dalci O. Evaluation of the effect of different attachment configurations on molar teeth in maxillary expansion with clear aligners – a finite element analysis. BMC Oral Health. 2024. doi:10.1186/s12903-024-04544-8
BibTeX
@article{Karsl2024,
author = {Karslı, Nurver and Ocak, Irmak and Akyıldız, Müge and Gögen, Hakan and Dalci, Oyku},
title = {Evaluation of the effect of different attachment configurations on molar teeth in maxillary expansion with clear aligners – a finite element analysis},
journal = {BMC Oral Health},
year = {2024},
doi = {10.1186/s12903-024-04544-8}
}
EUVIMED