EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of a novel 3-dimensional-printed attachment transfer method with conventional methods in clear aligner therapy: An in vitro study

Sabahattin Bor, Samet Özden

American Journal of Orthodontics and Dentofacial Orthopedics · 2026

DOI: 10.1016/j.ajodo.2025.09.031 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift American Journal of Orthodontics and Dentofacial Orthopedics, 2026. Verfasst von Sabahattin Bor und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Faculty of Dentistry, İnönü University, Malatya, Turkey. Electronic address: venaroshan@gmail.com. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Orthodontic Appliance Design, Orthodontic Appliances. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: This study aimed to compare the accuracy of a novel 3-dimensional (3D)-printed attachment transfer technique with conventional composite-based methods, evaluating the effect of template material and thickness. METHODS: Three transfer methods were investigated: nonflowable composite resin, flowable composite resin, and 3D-printed attachments with a transfer carrier. In the conventional attachment transfer method, 4 different thermoplastic template sheet thicknesses were used: 0.3, 0.5, 0.75, and 0.8 mm. A standardized reference model with 6 digitally planned attachments was used for all groups. Using each method, attachments were transferred to 3D-printed dental models, which were then scanned and superimposed with the reference model. Root mean square and mean distance values were calculated using CloudCompare software (version 2.14; www.danielgm.net/cc/) for surface deviation analysis. RESULTS: Statistically significant differences were observed among the attachment transfer methods (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalOrthodontic Appliance DesignOrthodontic AppliancesHumansComposite ResinsIn Vitro TechniquesModels, Dental

Substanzen

Composite Resins

Autor:innen und Institutionen

  • Department of Orthodontics, Faculty of Dentistry, İnönü University, Malatya, Turkey. Electronic address: venaroshan@gmail.com.
  • Department of Orthodontics, Faculty of Dentistry, İnönü University, Malatya, Turkey.

Zitieren

APA

Bor, S., & Özden, S. (2026). Comparison of a novel 3-dimensional-printed attachment transfer method with conventional methods in clear aligner therapy: An in vitro study. American Journal of Orthodontics and Dentofacial Orthopedics. https://doi.org/10.1016/j.ajodo.2025.09.031

Vancouver

Bor S, Özden S. Comparison of a novel 3-dimensional-printed attachment transfer method with conventional methods in clear aligner therapy: An in vitro study. American Journal of Orthodontics and Dentofacial Orthopedics. 2026. doi:10.1016/j.ajodo.2025.09.031

BibTeX
@article{Bor2026,
  author = {Bor, Sabahattin and Özden, Samet},
  title = {Comparison of a novel 3-dimensional-printed attachment transfer method with conventional methods in clear aligner therapy: An in vitro study},
  journal = {American Journal of Orthodontics and Dentofacial Orthopedics},
  year = {2026},
  doi = {10.1016/j.ajodo.2025.09.031}
}
Kostenlos starten →