Endoscope processing effectiveness: A reality check and call to action for infection preventionists and clinicians
American Journal of Infection Control · 2025
DOI: 10.1016/j.ajic.2025.04.003 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift American Journal of Infection Control, 2025. Verfasst von Cori L Ofstead und 3 weiteren Autor:innen. Beteiligte Einrichtung: Ofstead & Associates, Inc., Bloomington, MN. Electronic address: cori@ofsteadinsights.com. Hauptthemen laut MEDLINE: Disinfection, Endoscopes, Infection Control, Cross Infection. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 122 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Boston Scientific Corporation.
Abstract (Originalsprache)
BACKGROUND: Flexible endoscopes are heavily exposed to blood, mucus, and other secretions during procedures and may harbor billions of microbes before processing. Guidelines recommend thorough cleaning and sterilization or high-level disinfection (HLD) after each use. METHODS: This review describes evidence on the effectiveness of HLD from a robust review of peer-reviewed journals, adverse events reports posted by the Food and Drug Administration, and other government reports published during 2019-2024. RESULTS: Although HLD theoretically eliminates viruses, fungi, and bacteria (except a few resilient spores), numerous studies found it did not reliably eliminate microbes in real-world settings, and a large proportion of endoscopes harbored substantial bioburden and potential pathogens. Dozens of endoscopy-associated outbreaks have been reported in the past 5years, including several involving multidrug-resistant organisms. When contaminated endoscopes or endoscopy-associated infections were discovered, investigators commonly found that personnel were skipping essential steps or doing them improperly. DISCUSSION: To reduce infection risk and enhance patient safety, infection preventionists, clinicians, sterile processing and departmental managers, and other leaders should review the evidence, perform risk assessments, and implement proactive strategies for quality improvement in their facilities.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ofstead & Associates, Inc., Bloomington, MN. Electronic address: cori@ofsteadinsights.com.
- Ofstead & Associates, Inc., Bloomington, MN.
Förderung
- Boston Scientific Corporation
Zitieren
APA
Ofstead, C. L., Smart, A. G., Hurst, L. L., & Lamb, L. A. (2025). Endoscope processing effectiveness: A reality check and call to action for infection preventionists and clinicians. American Journal of Infection Control. https://doi.org/10.1016/j.ajic.2025.04.003
Vancouver
Ofstead CL, Smart AG, Hurst LL, Lamb LA. Endoscope processing effectiveness: A reality check and call to action for infection preventionists and clinicians. American Journal of Infection Control. 2025. doi:10.1016/j.ajic.2025.04.003
BibTeX
@article{Ofstead2025,
author = {Ofstead, Cori L and Smart, Abigail G and Hurst, Lydia L and Lamb, Larry A},
title = {Endoscope processing effectiveness: A reality check and call to action for infection preventionists and clinicians},
journal = {American Journal of Infection Control},
year = {2025},
doi = {10.1016/j.ajic.2025.04.003}
}
EUVIMED