Comparison of Titanium and Carbon Fiber-Reinforced Polyetheretherketone Spinal Implants in Postoperative Spine Stereotactic Body Radiation Therapy: A Comprehensive Review of Current Evidence and Future Perspectives
Advances in Radiation Oncology · 2026-11 · 11 (11) · 102136
DOI: 10.1016/j.adro.2026.102136 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Advances in Radiation Oncology, 2026-11. Verfasst von Yuhi Suda und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiation Oncology, Department of Radiology, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, Bunkyo-ku, Tokyo…. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, icotec ag.
Abstract (Originalsprache)
Postoperative stereotactic body radiation therapy (SBRT) for spinal metastases presents technical challenges, particularly in the presence of internal fixation devices. Titanium implants-the standard implant material-cause substantial imaging artifacts in computed tomography (CT) and magnetic resonance (MR) scans, which can lead to target and organ-at-risk contouring problems and compromise the accuracy of dose calculations. Meanwhile, carbon fiber-reinforced polyetheretherketone (Carbon/PEEK) implants have emerged as radiolucent alternatives with favorable imaging properties. This review summarizes the current evidence comparing titanium and Carbon/PEEK implants in the context of postoperative spine SBRT, focusing on differences in artifact size in CT and MR imaging, contouring accuracy, dose perturbation, dose calculation accuracy, image guided radiation therapy, radiation therapy robustness to setup error, and clinical outcomes in photon and proton therapies.
Autor:innen und Institutionen
- Division of Radiation Oncology, Department of Radiology, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, Bunkyo-ku, Tokyo, Japan.
- Department of Radiological Sciences, Komazawa University, Setagaya-ku, Tokyo, Japan.
Förderung
- Japan Society for the Promotion of Science
- icotec ag
Zitieren
APA
Suda, Y., Nakajima, Y., Ito, K., Watanabe, S., Taguchi, K., & Kito, S. (2026). Comparison of Titanium and Carbon Fiber-Reinforced Polyetheretherketone Spinal Implants in Postoperative Spine Stereotactic Body Radiation Therapy: A Comprehensive Review of Current Evidence and Future Perspectives. Advances in Radiation Oncology, 11(11), 102136. https://doi.org/10.1016/j.adro.2026.102136
Vancouver
Suda Y, Nakajima Y, Ito K, Watanabe S, Taguchi K, Kito S. Comparison of Titanium and Carbon Fiber-Reinforced Polyetheretherketone Spinal Implants in Postoperative Spine Stereotactic Body Radiation Therapy: A Comprehensive Review of Current Evidence and Future Perspectives. Advances in Radiation Oncology. 2026;11(11):102136. doi:10.1016/j.adro.2026.102136
BibTeX
@article{Suda2026,
author = {Suda, Yuhi and Nakajima, Yujiro and Ito, Kei and Watanabe, Shota and Taguchi, Kentaro and Kito, Satoshi},
title = {Comparison of Titanium and Carbon Fiber-Reinforced Polyetheretherketone Spinal Implants in Postoperative Spine Stereotactic Body Radiation Therapy: A Comprehensive Review of Current Evidence and Future Perspectives},
journal = {Advances in Radiation Oncology},
year = {2026},
volume = {11},
number = {11},
pages = {102136},
doi = {10.1016/j.adro.2026.102136}
}
EUVIMED