Development of Short-Titanium-Fiber-Reinforced Porous Titanium as Biometal for Implants
Journal of Composites Science · 02.01.2025 · 9 (1) · 10
DOI: 10.3390/jcs9010010 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Composites Science, online erschienen am 02.01.2025. Verfasst von So Shimizu und 2 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Japan Research Institute of Industrial Science (Fukuyama).
Abstract (Originalsprache)
Biometals used for the replacement of damaged bones are required to have a Young’s modulus comparable with that of the surrounding bones, in addition to having no toxicity, high corrosion resistance, and high strength. The Young’s modulus of natural bones is much lower than those of common biometals. Porous biometals have been widely studied to achieve a lower Young’s modulus. However, these materials commonly exhibit low strength because the pores tend to behave as microscopic defects. In this study, porous titanium, a promising biometal, was reinforced with short titanium fibers. The porous structure and fiber reinforcement provided a low Young’s modulus and relatively high strength, respectively. The short-titanium-fiber-reinforced porous titanium was fabricated using the space holder method with spark plasma sintering. The porosity of the matrix (uniform porous titanium), volume fraction of the fibers, and aspect ratio were set to 60%, 30%, and 8 to 64, respectively. A bending test revealed that the Young’s modulus was low and almost constant, irrespective of the aspect ratio, and that the strength increased with an increased aspect ratio. A high strength, which is difficult to obtain with uniform porous titanium, and a low Young’s modulus were achieved by applying fiber reinforcement. The results demonstrate that short-titanium-fiber-reinforced porous titanium is a candidate biometal for the replacement of damaged bones.
Förderung
- The Japan Research Institute of Industrial Science (Fukuyama)
Zitieren
APA
Shimizu, S., Fujii, T., & Shimamura, Y. (2025). Development of Short-Titanium-Fiber-Reinforced Porous Titanium as Biometal for Implants. Journal of Composites Science, 9(1), 10. https://doi.org/10.3390/jcs9010010
Vancouver
Shimizu S, Fujii T, Shimamura Y. Development of Short-Titanium-Fiber-Reinforced Porous Titanium as Biometal for Implants. Journal of Composites Science. 2025;9(1):10. doi:10.3390/jcs9010010
BibTeX
@article{Shimizu2025,
author = {Shimizu, So and Fujii, Tomoyuki and Shimamura, Yoshinobu},
title = {Development of Short-Titanium-Fiber-Reinforced Porous Titanium as Biometal for Implants},
journal = {Journal of Composites Science},
year = {2025},
volume = {9},
number = {1},
pages = {10},
doi = {10.3390/jcs9010010}
}
EUVIMED