EUVIMEDEUVIMED entdecken
Crossref

3D monitoring of the microphase separations inside the intraocular lens

Yan Mao, Xiao Liang, Junpeng Zhao, Lingxiang Jiang, Qingyou Liang, To Ngai, Xiangjun Gong, Mingxing Wu

Acta Biomaterialia · 2024-03 · 177 · 178-188

DOI: 10.1016/j.actbio.2024.01.035 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Biomaterialia, 2024-03. Verfasst von Yan Mao und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and …. Hauptthemen laut MEDLINE: Lenses, Intraocular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: South China University of Technology, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Glistenings often occur after implanting the intraocular lens (IOL) due to the formation of numerous microvacuoles (MVs) and may lead to deterioration of vision quality. Previous studies showed the formation of MVs was associated with the hydrophobicity of IOL materials. Yet, the mechanism remains an open question due to the complexity of IOL polymer networks. In this study, two commercialized IOLs with similar hydrophobicity are found distinct in the formation of MVs. The 3D growth kinetics of MVs during cooling processes are captured for the first time by digital holographic microscopy (DHM) and the components of MVs are measured by DHM and Raman spectroscopy. The results reveal that the growth of MVs stems from the microphase separation of water and surrounding IOL polymers. A polymer swelling model is thus proposed to describe the microphase separation process which is found dependent on the elasticity of IOL polymer networks. The total volume of MVs is determined by the IOL hydrophobicity, while the elastic force of IOL polymer networks determines the number density and size of MVs. This study demonstrates an approach for characterizing the phase separation of crosslinked polymeric materials in biosystems and sheds lights on the refinement of IOL materials. STATEMENT OF SIGNIFICANCE: Glistenings due to the formation of numerous microvacuoles (MVs) in intraocular lens (IOL) can occur after IOL implantation, which may induce poor quality of vision. However, the underlying mechanism of MVs formation is still an open question. This study establishes an in-situ 3D imaging platform to monitor growth kinetics of the MVs in IOLs, which allows to uncover the mechanism of glistenings formation resulting from the microphase separation. The findings imply the material hydrophobicity influences the total volume of MVs, while the local elasticity of IOL polymer networks determines the number density and the size of MVs. This study offers a new approach for characterizing phase separation in crosslinking biosystems and sheds lights on the refinement of IOL materials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularPolymersAcrylic ResinsHydrophobic and Hydrophilic Interactions

Stichwörter der Autor:innen

3D imagingCrosslinking polymerGlisteningsMicrovacuoles formationPhase separation

Substanzen

PolymersAcrylic Resins

Autor:innen und Institutionen

  • State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou 510060, PR China.
  • Faculty of Material Science and Engineering, South China University of Technology, Guangzhou 510640, PR China.
  • South China Advanced Institute for Soft Matter Science and Technology (AISMST), School of Emergent Soft Matter, South China University of Technology, Guangzhou 510640, PR China.
  • Faculty of Material Science and Engineering, South China University of Technology, Guangzhou 510640, PR China; Analytical and Testing Center, South China University of Technology, Guangzhou 510640, PR China.
  • Department of Chemistry, The Chinese University of Hong Kong, Hong Kong 999077, PR China.
  • Faculty of Material Science and Engineering, South China University of Technology, Guangzhou 510640, PR China; Guangdong Provincial Key Laboratory of Luminescence from Molecular Aggregates, South China University of Tec…

Förderung

  • South China University of Technology
  • National Natural Science Foundation of China

Zitieren

APA

Mao, Y., Liang, X., Zhao, J., Jiang, L., Liang, Q., Ngai, T., Gong, X., & Wu, M. (2024). 3D monitoring of the microphase separations inside the intraocular lens. Acta Biomaterialia, 177, 178-188. https://doi.org/10.1016/j.actbio.2024.01.035

Vancouver

Mao Y, Liang X, Zhao J, Jiang L, Liang Q, Ngai T, et al. 3D monitoring of the microphase separations inside the intraocular lens. Acta Biomaterialia. 2024;177:178-188. doi:10.1016/j.actbio.2024.01.035

BibTeX
@article{Mao2024,
  author = {Mao, Yan and Liang, Xiao and Zhao, Junpeng and Jiang, Lingxiang and Liang, Qingyou and Ngai, To and Gong, Xiangjun and Wu, Mingxing},
  title = {3D monitoring of the microphase separations inside the intraocular lens},
  journal = {Acta Biomaterialia},
  year = {2024},
  volume = {177},
  pages = {178--188},
  doi = {10.1016/j.actbio.2024.01.035}
}
Kostenlos starten →